摘要This paper presents a kinematic calibration of a 6-RRRPRR parallel kinematic mechanism with offset RR-joints that would be applied in space positioning field. In order to ensure highly accurate and highly effective calibration process, the complete error model, which contains offset universal joint errors, is established by differentiating inverse kinematic model. A calibration simulation comparison with non-complete error model shows that offset universal joint errors are crucial to improve the calibration accuracy. Using the error model, an optimal calibration configuration selection algorithm is developed to determine the least number of measurement configurations as well as the optimal selection of these configurations from the feasible configuration set. To verify the effectiveness of kinematic calibration, a simulation and experiment were performed. The results show that the developed approach can effectively improve accuracy of a parallel kinematic mechanism with relatively low number of calibration configurations.
关键词Parallel kinematic machine,complete error model,observability index,optimal measurement configurations,calibration experiment,identifiable parameters,robot calibration,stiffness,design
DOI10.1177/0954406219869985
URL查看原文
收录类别SCI
语种英语
引用统计
文献类型期刊论文
条目标识符http://ir.ciomp.ac.cn/handle/181722/63350
专题中国科学院长春光学精密机械与物理研究所
推荐引用方式
GB/T 7714
C.Y.Han,Y.Yu,Z.B.Xu,et al. Complete kinematic calibration of a 6-RRRPRR parallel kinematic machine based on the optimal measurement configurations[J]. Proceedings of the Institution of Mechanical Engineers Part C-Journal of Mechanical Engineering Science,2019,234(1):121-136.
APA C.Y.Han,Y.Yu,Z.B.Xu,X.M.Wang,P.Yu,&X.Q.Zhou.(2019).Complete kinematic calibration of a 6-RRRPRR parallel kinematic machine based on the optimal measurement configurations.Proceedings of the Institution of Mechanical Engineers Part C-Journal of Mechanical Engineering Science,234(1),121-136.
MLA C.Y.Han,et al."Complete kinematic calibration of a 6-RRRPRR parallel kinematic machine based on the optimal measurement configurations".Proceedings of the Institution of Mechanical Engineers Part C-Journal of Mechanical Engineering Science 234.1(2019):121-136.
条目包含的文件 下载所有文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
Complete kinematic c(2276KB)期刊论文出版稿开放获取CC BY-NC-SA浏览 下载
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[C.Y.Han]的文章
[Y.Yu]的文章
[Z.B.Xu]的文章
百度学术
百度学术中相似的文章
[C.Y.Han]的文章
[Y.Yu]的文章
[Z.B.Xu]的文章
必应学术
必应学术中相似的文章
[C.Y.Han]的文章
[Y.Yu]的文章
[Z.B.Xu]的文章
相关权益政策
暂无数据
收藏/分享
文件名: Complete kinematic calibration of a 6RRRPRR p.pdf
格式: Adobe PDF
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。