Measurement and calibration of optical axis changes caused by gravity for ground-based large-aperture telescope
H. Wang; J. Wang; T. Chen; Y. Cao and B. Chen
2022
发表期刊Guangxue Jingmi Gongcheng/Optics and Precision Engineering
ISSN1004924X
卷号30期号:23页码:3021-3030
摘要As the diameter of ground-based telescopes increases, the structural size of the telescope also increases accordingly, and the effect of the telescopes optical axis pointing caused by gravity becomes increasingly pronounced. The measurement and calibration of optical axis changes for ground-based large-aperture telescopes is a necessary prerequisite to obtaining high-precision orbital target data. To realize the estimation, measurement, and active correction of the telescope pointing error, the optical axis changing rules of the telescope system are analyzed from the structure of the telescope's opt-mechanical system, and an optical axis change measurement and calibration method of the is proposed. The experimental results show that the maximum relative change of the optical axis is 126when the telescope is at low elevation. The main factor causing the pointing change is the effect of gravity on the telescope truss structure. Finally, a calibration model based on the secondary mirror adjustment structure and the coma-free theory of the Cassegrain system is proposed to improve the tracking performance of the 4-meter aperture telescope. The maximum relative change in the optical axis of the telescope after calibration is within 3. According to the test results, the ground-based large telescope pointing change measurement and calibration method can be applied to the calibration and mounting process of the telescope. 2022 Chinese Academy of Sciences. All rights reserved.
DOI10.37188/OPE.20223023.3021
URL查看原文
收录类别ei
引用统计
文献类型期刊论文
条目标识符http://ir.ciomp.ac.cn/handle/181722/66830
专题中国科学院长春光学精密机械与物理研究所
推荐引用方式
GB/T 7714
H. Wang,J. Wang,T. Chen,et al. Measurement and calibration of optical axis changes caused by gravity for ground-based large-aperture telescope[J]. Guangxue Jingmi Gongcheng/Optics and Precision Engineering,2022,30(23):3021-3030.
APA H. Wang,J. Wang,T. Chen,&Y. Cao and B. Chen.(2022).Measurement and calibration of optical axis changes caused by gravity for ground-based large-aperture telescope.Guangxue Jingmi Gongcheng/Optics and Precision Engineering,30(23),3021-3030.
MLA H. Wang,et al."Measurement and calibration of optical axis changes caused by gravity for ground-based large-aperture telescope".Guangxue Jingmi Gongcheng/Optics and Precision Engineering 30.23(2022):3021-3030.
条目包含的文件 下载所有文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
Measurement and cali(2171KB)期刊论文出版稿开放获取CC BY-NC-SA浏览 下载
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[H. Wang]的文章
[J. Wang]的文章
[T. Chen]的文章
百度学术
百度学术中相似的文章
[H. Wang]的文章
[J. Wang]的文章
[T. Chen]的文章
必应学术
必应学术中相似的文章
[H. Wang]的文章
[J. Wang]的文章
[T. Chen]的文章
相关权益政策
暂无数据
收藏/分享
文件名: Measurement and calibration of optical axis ch.pdf
格式: Adobe PDF
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。