CIOMP OpenIR
Fiber micro-tip temperature sensor based on cholesteric liquid crystal
J. Y. Hu,D. Zhou,Y. M. Su,S. Q. Liu,P. X. Miao,Y. C. Shi,W. M. Sun and Y. J. Liu
2020
发表期刊Optics Letters
ISSN0146-9592
卷号45期号:18页码:5209-5212
摘要This Letter proposes and demonstrates a novel, miniature fiber-tip temperature sensor with a tapered hollow capillary tube (HCT) filled with glycerin and dye-doped cholesteric liquid crystal (CLC). The function of glycerin is to provide a surface anchoring force to control the uniform orientation of CLC molecules, so that the CLC in the tapered HCT can be considered as a mirrorless photonic bandgap (PBG) microcavity. An unambiguously identifiable PBG mode single peak appears in the emission spectra of the sensor. The CLC-based fiber-tip temperature sensor has a temperature sensitivity of -9.167 nm/degrees C, and the figure of merit can reach 67.4 degrees C-1. This sensor offers key features and advantages, including compactness, unambiguous identifiability, and biocompatibility, which can satisfy requirements of temperature measurement in various temperature sensing application fields and has great potential for biochemical detection at cell level. In addition, the CLC was integrated into the optical fiber terminal, and the PBC mode is excited, collected and transmitted by the multimode fiber coupler, which is reported for the first time, to the best of our knowledge. (C) 2020 Optical Society of America
DOI10.1364/ol.402473
URL查看原文
收录类别SCI ; EI
语种英语
引用统计
文献类型期刊论文
条目标识符http://ir.ciomp.ac.cn/handle/181722/64526
专题中国科学院长春光学精密机械与物理研究所
推荐引用方式
GB/T 7714
J. Y. Hu,D. Zhou,Y. M. Su,S. Q. Liu,P. X. Miao,Y. C. Shi,W. M. Sun and Y. J. Liu. Fiber micro-tip temperature sensor based on cholesteric liquid crystal[J]. Optics Letters,2020,45(18):5209-5212.
APA J. Y. Hu,D. Zhou,Y. M. Su,S. Q. Liu,P. X. Miao,Y. C. Shi,W. M. Sun and Y. J. Liu.(2020).Fiber micro-tip temperature sensor based on cholesteric liquid crystal.Optics Letters,45(18),5209-5212.
MLA J. Y. Hu,D. Zhou,Y. M. Su,S. Q. Liu,P. X. Miao,Y. C. Shi,W. M. Sun and Y. J. Liu."Fiber micro-tip temperature sensor based on cholesteric liquid crystal".Optics Letters 45.18(2020):5209-5212.
条目包含的文件 下载所有文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
Fiber micro-tip temp(599KB)期刊论文出版稿开放获取CC BY-NC-SA浏览 下载
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[J. Y. Hu,D. Zhou,Y. M. Su,S. Q. Liu,P. X. Miao,Y. C. Shi,W. M. Sun and Y. J. Liu]的文章
百度学术
百度学术中相似的文章
[J. Y. Hu,D. Zhou,Y. M. Su,S. Q. Liu,P. X. Miao,Y. C. Shi,W. M. Sun and Y. J. Liu]的文章
必应学术
必应学术中相似的文章
[J. Y. Hu,D. Zhou,Y. M. Su,S. Q. Liu,P. X. Miao,Y. C. Shi,W. M. Sun and Y. J. Liu]的文章
相关权益政策
暂无数据
收藏/分享
文件名: Fiber micro-tip temperature sensor based on ch.pdf
格式: Adobe PDF
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。