CIOMP OpenIR
Easily implemented approach for the calibration of alignment and retardation errors in a channeled spectropolarimeter
Ju, X. P.; Yang, B.; Yan, C. X.; Zhang, J. Q.; Xing, W. H.
2018
发表期刊Applied Optics
ISSN1559-128X
卷号57期号:29页码:8600-8613
摘要Calibration of the channeled spectropolarimeter is significant for the quantitative application of this instrument. In current calibration methods for a channeled spectropolarimeter, an absolute angle between the coordinate system of an auxiliary polarizer and the global coordinate system of the instrument is usually indispensable. The effectiveness of calibration depends on the precision of the absolute angle, while it is usually difficult to achieve in a practical calibration process. This paper presents an easily implemented method to simultaneously calibrate the alignment and retardation errors of high-order retarders for a channeled spectropolarimeter. In the presented method, the requirement of an absolute angle between the coordinate system of an auxiliary polarizer and the global coordinate system of the instrument is replaced by only rotating a relative angle in the coordinate system of the auxiliary polarizer itself. First, we theoretically derive the modified reconstruction model considering the alignment errors of high-order retarders. By analyzing and summarizing the modified reconstruction model, the calibration and compensation models of the alignment and retardation errors are further proposed. Then, two linearly polarized beams with a relative angle of 45 degrees between them are utilized to determine the alignment and retardation errors. Based on these results, the alignment and retardation errors can be compensated by a software correction algorithm without any precise mechanical adjustments. The effectiveness and feasibility of the presented method are verified by numerical simulations and experiments. The advantage of easy implementation makes this calibration method more suitable to apply in the laboratory and to be on track for correcting the channeled spectropolarimeter. (C) 2018 Optical Society of America
关键词polarimetry parameters reduction noise Optics
DOI10.1364/ao.57.008600
收录类别SCI ; EI
引用统计
文献类型期刊论文
条目标识符http://ir.ciomp.ac.cn/handle/181722/60962
专题中国科学院长春光学精密机械与物理研究所
推荐引用方式
GB/T 7714
Ju, X. P.,Yang, B.,Yan, C. X.,et al. Easily implemented approach for the calibration of alignment and retardation errors in a channeled spectropolarimeter[J]. Applied Optics,2018,57(29):8600-8613.
APA Ju, X. P.,Yang, B.,Yan, C. X.,Zhang, J. Q.,&Xing, W. H..(2018).Easily implemented approach for the calibration of alignment and retardation errors in a channeled spectropolarimeter.Applied Optics,57(29),8600-8613.
MLA Ju, X. P.,et al."Easily implemented approach for the calibration of alignment and retardation errors in a channeled spectropolarimeter".Applied Optics 57.29(2018):8600-8613.
条目包含的文件 下载所有文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
Easily implemented a(2079KB)期刊论文出版稿开放获取CC BY-NC-SA浏览 下载
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Ju, X. P.]的文章
[Yang, B.]的文章
[Yan, C. X.]的文章
百度学术
百度学术中相似的文章
[Ju, X. P.]的文章
[Yang, B.]的文章
[Yan, C. X.]的文章
必应学术
必应学术中相似的文章
[Ju, X. P.]的文章
[Yang, B.]的文章
[Yan, C. X.]的文章
相关权益政策
暂无数据
收藏/分享
文件名: Easily implemented approach for the calibratio.pdf
格式: Adobe PDF
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。