AbstractThis article first reviews the main characteristics of the High-Resolution Hyperspectral Sensor for carbon observation Grating Spectrometer (HRHS-GS) and discusses the impact of spectral resolution on gas absorption lines. The major content of this article is the laboratory calibration of HRHS-GS, the signal-to-noise ratio (SNR), instrument line shape (ILS), and the spectral resolution of each channel were achieved. The SNR results met the mission requirements for the 0.76 mu m band, but missed the requirement for the two Carbon dioxide (CO2) bands. To address this problem, the model 'Multiplex Merging of Spectral Pixels' was established to improve the SNR by increasing the incident energy of a single spectral channel. This process would lead to spectral broadening; the spectral resolution before and after that process was obtained. The transmittance spectra before and after multiplex merging were compared by the line-by-line radiative transfer model (LBLRTM) to analyse the impact of spectral broadening on gas absorption lines. Next, the results were verified by experiment with a gas absorption cell. The results showed that 'Multiplex Merging of Spectral Pixels' could effectively improve the SNR. For the 0.76 mu m band, the transmittance spectra before and after multiplex merging were almost the same; for the 1.61 mu m band, the peak value of the transmittance spectra decays by about 5%; and for the 2.06 mu m band, the attenuation of the transmittance spectra is smaller than 3%. Meanwhile, the spectral resolution after spectral broadening still satisfied the study's requirement.
Indexed Bysci ; ei
Language英语
WOS IDWOS:000399247300003
Citation statistics
Cited Times:4[WOS]   [WOS Record]     [Related Records in WOS]
Document Type期刊论文
Identifierhttp://ir.ciomp.ac.cn/handle/181722/59422
Collection中科院长春光机所知识产出
Recommended Citation
GB/T 7714
Zhang, H.,Y. Zheng,C. Lin,et al. Laboratory spectral calibration of TanSat and the influence of multiplex merging of pixels[J]. International Journal of Remote Sensing,2017,38(13).
APA Zhang, H.,Y. Zheng,C. Lin,W. Wang,&Q. Wang and S. Li.(2017).Laboratory spectral calibration of TanSat and the influence of multiplex merging of pixels.International Journal of Remote Sensing,38(13).
MLA Zhang, H.,et al."Laboratory spectral calibration of TanSat and the influence of multiplex merging of pixels".International Journal of Remote Sensing 38.13(2017).
Files in This Item: Download All
File Name/Size DocType Version Access License
Laboratory spectral (3176KB)期刊论文作者接受稿开放获取CC BY-NC-SAView Download
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Google Scholar
Similar articles in Google Scholar
[Zhang, H.]'s Articles
[Y. Zheng]'s Articles
[C. Lin]'s Articles
Baidu academic
Similar articles in Baidu academic
[Zhang, H.]'s Articles
[Y. Zheng]'s Articles
[C. Lin]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[Zhang, H.]'s Articles
[Y. Zheng]'s Articles
[C. Lin]'s Articles
Terms of Use
No data!
Social Bookmark/Share
File name: Laboratory spectral calibration.pdf
Format: Adobe PDF
This file does not support browsing at this time
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.