CIOMP OpenIR  > 中科院长春光机所知识产出
Radiometric Calibration Based on Low-temperature Area Blackbody for Infrared Systems with High Dynamic Range
Tian, Q.-J.; S.-T. Chang; Y.-F. Qiao and F.-Y. He
2017
发表期刊Guangzi Xuebao/Acta Photonica Sinica
卷号46期号:4
摘要To overcome the restrictions of long calibration time, high cost and poor maneuverability for radiometric calibration of the ground-based infrared radiometric measurement systems with large aperture, a radiometric calibration method, which is based on low-temperature area blackbody, for infrared systems with high dynamic range was proposed. First of all, the neutral-density filter in the system was measured to obtain its actual transmissivity and calculate its radiance. Secondly, the radiometric calibration was performed using low-temperature blackbody at two integration times. The response and stray radiation of the system as well as the bias of the detector were obtained on the basis of the calibration results. Then, the calibration results at high dynamic range could be acquired by extrapolating the low-temperature calibration results, combined with the measured characteristics of the neutral-density filter. To verify the effectiveness of the proposed method, a 600mm infrared system was calibrated at high dynamic range, using the proposed method and the typical method of high-temperature blackbody and large aperture collimator. The experimental results indicate that the error of the proposed method is less than 10.25%, which means the proposed method can be used to perform calibration for the system. The radiometric calibration for infrared systems with high dynamic range can be achieved only with a low-temperature blackbody in the outfield. The proposed method, with the advantages of simple operation and strong real-time, has a value for application. 2017, Science Press. All right reserved.
收录类别ei
语种中文
文献类型期刊论文
条目标识符http://ir.ciomp.ac.cn/handle/181722/59231
专题中科院长春光机所知识产出
推荐引用方式
GB/T 7714
Tian, Q.-J.,S.-T. Chang,Y.-F. Qiao and F.-Y. He. Radiometric Calibration Based on Low-temperature Area Blackbody for Infrared Systems with High Dynamic Range[J]. Guangzi Xuebao/Acta Photonica Sinica,2017,46(4).
APA Tian, Q.-J.,S.-T. Chang,&Y.-F. Qiao and F.-Y. He.(2017).Radiometric Calibration Based on Low-temperature Area Blackbody for Infrared Systems with High Dynamic Range.Guangzi Xuebao/Acta Photonica Sinica,46(4).
MLA Tian, Q.-J.,et al."Radiometric Calibration Based on Low-temperature Area Blackbody for Infrared Systems with High Dynamic Range".Guangzi Xuebao/Acta Photonica Sinica 46.4(2017).
条目包含的文件 下载所有文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
Radiometric Calibrat(507KB)期刊论文作者接受稿开放获取CC BY-NC-SA浏览 下载
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Tian, Q.-J.]的文章
[S.-T. Chang]的文章
[Y.-F. Qiao and F.-Y. He]的文章
百度学术
百度学术中相似的文章
[Tian, Q.-J.]的文章
[S.-T. Chang]的文章
[Y.-F. Qiao and F.-Y. He]的文章
必应学术
必应学术中相似的文章
[Tian, Q.-J.]的文章
[S.-T. Chang]的文章
[Y.-F. Qiao and F.-Y. He]的文章
相关权益政策
暂无数据
收藏/分享
文件名: Radiometric Calibration Based on.pdf
格式: Adobe PDF
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。