CIOMP OpenIR  > 中科院长春光机所知识产出
Radiometric Calibration Based on Low-temperature Area Blackbody for Infrared Systems with High Dynamic Range
Tian, Q.-J.; S.-T. Chang; Y.-F. Qiao and F.-Y. He
2017
Source PublicationGuangzi Xuebao/Acta Photonica Sinica
Volume46Issue:4
AbstractTo overcome the restrictions of long calibration time, high cost and poor maneuverability for radiometric calibration of the ground-based infrared radiometric measurement systems with large aperture, a radiometric calibration method, which is based on low-temperature area blackbody, for infrared systems with high dynamic range was proposed. First of all, the neutral-density filter in the system was measured to obtain its actual transmissivity and calculate its radiance. Secondly, the radiometric calibration was performed using low-temperature blackbody at two integration times. The response and stray radiation of the system as well as the bias of the detector were obtained on the basis of the calibration results. Then, the calibration results at high dynamic range could be acquired by extrapolating the low-temperature calibration results, combined with the measured characteristics of the neutral-density filter. To verify the effectiveness of the proposed method, a 600mm infrared system was calibrated at high dynamic range, using the proposed method and the typical method of high-temperature blackbody and large aperture collimator. The experimental results indicate that the error of the proposed method is less than 10.25%, which means the proposed method can be used to perform calibration for the system. The radiometric calibration for infrared systems with high dynamic range can be achieved only with a low-temperature blackbody in the outfield. The proposed method, with the advantages of simple operation and strong real-time, has a value for application. 2017, Science Press. All right reserved.
Indexed Byei
Language中文
Document Type期刊论文
Identifierhttp://ir.ciomp.ac.cn/handle/181722/59231
Collection中科院长春光机所知识产出
Recommended Citation
GB/T 7714
Tian, Q.-J.,S.-T. Chang,Y.-F. Qiao and F.-Y. He. Radiometric Calibration Based on Low-temperature Area Blackbody for Infrared Systems with High Dynamic Range[J]. Guangzi Xuebao/Acta Photonica Sinica,2017,46(4).
APA Tian, Q.-J.,S.-T. Chang,&Y.-F. Qiao and F.-Y. He.(2017).Radiometric Calibration Based on Low-temperature Area Blackbody for Infrared Systems with High Dynamic Range.Guangzi Xuebao/Acta Photonica Sinica,46(4).
MLA Tian, Q.-J.,et al."Radiometric Calibration Based on Low-temperature Area Blackbody for Infrared Systems with High Dynamic Range".Guangzi Xuebao/Acta Photonica Sinica 46.4(2017).
Files in This Item: Download All
File Name/Size DocType Version Access License
Radiometric Calibrat(507KB)期刊论文作者接受稿开放获取CC BY-NC-SAView Download
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Google Scholar
Similar articles in Google Scholar
[Tian, Q.-J.]'s Articles
[S.-T. Chang]'s Articles
[Y.-F. Qiao and F.-Y. He]'s Articles
Baidu academic
Similar articles in Baidu academic
[Tian, Q.-J.]'s Articles
[S.-T. Chang]'s Articles
[Y.-F. Qiao and F.-Y. He]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[Tian, Q.-J.]'s Articles
[S.-T. Chang]'s Articles
[Y.-F. Qiao and F.-Y. He]'s Articles
Terms of Use
No data!
Social Bookmark/Share
File name: Radiometric Calibration Based on.pdf
Format: Adobe PDF
This file does not support browsing at this time
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.