CIOMP OpenIR  > 中科院长春光机所知识产出
A method to measure internal stray radiation of cryogenic infrared imaging systems under various ambient temperatures
Tian, Q. J.; S. T. Chang; Z. Li; F. Y. He and Y. F. Qiao
2017
Source PublicationInfrared Physics & Technology
Volume81
AbstractThe suppression level of internal stray radiation is a key criterion for infrared imaging systems, especially for high-precision cryogenic infrared imaging systems. To achieve accurate measurement for internal stray radiation of cryogenic infrared imaging systems under various ambient temperatures, a measurement method, which is based on radiometric calibration, is presented in this paper. First of all, the calibration formula is deduced considering the integration time, and the effect of ambient temperature on internal stray radiation is further analyzed in detail. Then, an approach is proposed to measure the internal stray radiation of cryogenic infrared imaging systems under various ambient temperatures. By calibrating the system under two ambient temperatures, the quantitative relation between the internal stray radiation and the ambient temperature can be acquired, and then the internal stray radiation of the cryogenic infrared imaging system under various ambient temperatures can be calculated. Finally, several experiments are performed in a chamber with controllable inside temperatures to evaluate the effectiveness of the proposed method. Experimental results indicate that the proposed method can be used to measure internal stray radiation with high accuracy at various ambient temperatures and integration times. The proposed method has some advantages, such as simple implementation and the capability of high-precision measurement. The measurement results can be used to guide the stray radiation suppression and to test whether the internal stray radiation suppression performance meets the requirement or not. (C) 2016 Elsevier B.V. All rights reserved.
Indexed Bysci ; ei
Language英语
Document Type期刊论文
Identifierhttp://ir.ciomp.ac.cn/handle/181722/59229
Collection中科院长春光机所知识产出
Recommended Citation
GB/T 7714
Tian, Q. J.,S. T. Chang,Z. Li,et al. A method to measure internal stray radiation of cryogenic infrared imaging systems under various ambient temperatures[J]. Infrared Physics & Technology,2017,81.
APA Tian, Q. J.,S. T. Chang,Z. Li,&F. Y. He and Y. F. Qiao.(2017).A method to measure internal stray radiation of cryogenic infrared imaging systems under various ambient temperatures.Infrared Physics & Technology,81.
MLA Tian, Q. J.,et al."A method to measure internal stray radiation of cryogenic infrared imaging systems under various ambient temperatures".Infrared Physics & Technology 81(2017).
Files in This Item: Download All
File Name/Size DocType Version Access License
A method to measure (720KB)期刊论文作者接受稿开放获取CC BY-NC-SAView Download
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Google Scholar
Similar articles in Google Scholar
[Tian, Q. J.]'s Articles
[S. T. Chang]'s Articles
[Z. Li]'s Articles
Baidu academic
Similar articles in Baidu academic
[Tian, Q. J.]'s Articles
[S. T. Chang]'s Articles
[Z. Li]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[Tian, Q. J.]'s Articles
[S. T. Chang]'s Articles
[Z. Li]'s Articles
Terms of Use
No data!
Social Bookmark/Share
File name: A method to measure internal stray radiation.pdf
Format: Adobe PDF
This file does not support browsing at this time
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.