CIOMP OpenIR  > 中科院长春光机所知识产出
Radiometric calibration of hyper-spectral imaging spectrometer based on optimizing multi-spectral band selection
Sun, L.-w.; X. Ye; W. Fang; Z.-l. He; X.-l. Yi and Y.-p. Wang
2017
Source PublicationOptoelectronics Letters
Volume13Issue:6
AbstractHyper-spectral imaging spectrometer has high spatial and spectral resolution. Its radiometric calibration needs the knowledge of the sources used with high spectral resolution. In order to satisfy the requirement of source, an on-orbit radiometric calibration method is designed in this paper. This chain is based on the spectral inversion accuracy of the calibration light source. We compile the genetic algorithm progress which is used to optimize the channel design of the transfer radiometer and consider the degradation of the halogen lamp, thus realizing the high accuracy inversion of spectral curve in the whole working time. The experimental results show the average root mean squared error is 0.396%, the maximum root mean squared error is 0.448%, and the relative errors at all wavelengths are within 1% in the spectral range from 500 nm to 900 nm during 100 h operating time. The design lays a foundation for the high accuracy calibration of imaging spectrometer. 2017, Tianjin University of Technology and Springer-Verlag GmbH Germany, part of Springer Nature.
Indexed Bysci ; ei
Language英语
Document Type期刊论文
Identifierhttp://ir.ciomp.ac.cn/handle/181722/59203
Collection中科院长春光机所知识产出
Recommended Citation
GB/T 7714
Sun, L.-w.,X. Ye,W. Fang,et al. Radiometric calibration of hyper-spectral imaging spectrometer based on optimizing multi-spectral band selection[J]. Optoelectronics Letters,2017,13(6).
APA Sun, L.-w.,X. Ye,W. Fang,Z.-l. He,&X.-l. Yi and Y.-p. Wang.(2017).Radiometric calibration of hyper-spectral imaging spectrometer based on optimizing multi-spectral band selection.Optoelectronics Letters,13(6).
MLA Sun, L.-w.,et al."Radiometric calibration of hyper-spectral imaging spectrometer based on optimizing multi-spectral band selection".Optoelectronics Letters 13.6(2017).
Files in This Item: Download All
File Name/Size DocType Version Access License
Radiometric calibrat(500KB)期刊论文作者接受稿开放获取CC BY-NC-SAView Download
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Google Scholar
Similar articles in Google Scholar
[Sun, L.-w.]'s Articles
[X. Ye]'s Articles
[W. Fang]'s Articles
Baidu academic
Similar articles in Baidu academic
[Sun, L.-w.]'s Articles
[X. Ye]'s Articles
[W. Fang]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[Sun, L.-w.]'s Articles
[X. Ye]'s Articles
[W. Fang]'s Articles
Terms of Use
No data!
Social Bookmark/Share
File name: Radiometric calibration.pdf
Format: Adobe PDF
This file does not support browsing at this time
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.