CIOMP OpenIR  > 中科院长春光机所知识产出
Correction of cavity absorptance measure method for cryogenic radiometer
Yi, X. L.; W. Fang; Y. Luo; Z. W. Xia and Y. P. Wang
2016
发表期刊Iet Science Measurement & Technology
卷号10期号:6
摘要Solar Irradiance Absolute Radiometer (SIAR) is a cavity-type electrical substitution radiometer for transferring the World Radiance Reference (WRR). In order to shorten the measurement period, and ensure the measurement precision, the cavity temperature response model is experimentally investigated and corrected. The thermodynamic equation of cavity temperature is solved. Based on the analysis of non-equivalent in optical and electrical heating, the cavity temperature response model is corrected to a double exponential form. The simulation result analyzes the origin of the temperature pulse. A new characteristic parameter, named as non-equivalent response time, is proposed and measured. The cavity temperature response characteristic of SIAR is improved by the compensation of the temperature pulse. Comparison experiment results illustrate that the temperature pulse can be compensated by inserting a delay time, and the cavity temperature response model is simplified to a single exponential form. Thus, SIAR with large thermal time constant can adopt shorter measurement period, meanwhile measurement precision is 0.07%. The investigation of non-equivalent response time is important for the radiant calibration of SIAR. This correction method can also be used to optimize the on-orbit calibration method of Total Solar Irradiance Monitor (TSIM). 2016 SERSC.
文章类型期刊
收录类别SCI ; EI
语种英语
文献类型期刊论文
条目标识符http://ir.ciomp.ac.cn/handle/181722/57368
专题中科院长春光机所知识产出
推荐引用方式
GB/T 7714
Yi, X. L.,W. Fang,Y. Luo,et al. Correction of cavity absorptance measure method for cryogenic radiometer[J]. Iet Science Measurement & Technology,2016,10(6).
APA Yi, X. L.,W. Fang,Y. Luo,&Z. W. Xia and Y. P. Wang.(2016).Correction of cavity absorptance measure method for cryogenic radiometer.Iet Science Measurement & Technology,10(6).
MLA Yi, X. L.,et al."Correction of cavity absorptance measure method for cryogenic radiometer".Iet Science Measurement & Technology 10.6(2016).
条目包含的文件 下载所有文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
Correction of cavity(518KB)期刊论文作者接受稿开放获取CC BY-NC-SA浏览 下载
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Yi, X. L.]的文章
[W. Fang]的文章
[Y. Luo]的文章
百度学术
百度学术中相似的文章
[Yi, X. L.]的文章
[W. Fang]的文章
[Y. Luo]的文章
必应学术
必应学术中相似的文章
[Yi, X. L.]的文章
[W. Fang]的文章
[Y. Luo]的文章
相关权益政策
暂无数据
收藏/分享
文件名: Correction of cavity absorptance measure method for cryogenic radiometer.pdf
格式: Adobe PDF
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。