Changchun Institute of Optics,Fine Mechanics and Physics,CAS
TMT tertiary mirror axis calibration with laser tracker | |
An, Q.-c.; J.-x. Zhang; F. Yang and J.-w. Sun | |
2015 | |
发表期刊 | Optoelectronics Letters |
卷号 | 11期号:2页码:84-87 |
摘要 | To calibrate the tracing performance of the thirty meter telescope (TMT) tertiary mirror, for the special requirement of the TMT, the laser tracker is used to verify the motion. Firstly, the deviation is divided into two parts, namely, the repeatable error and the unrepeatable part. Then, based on the laser tracker, the mearturement and evalutation methods of the rigid body motion for the mirror are established, and the Monte Carol method is used to determine the accuracy of the mothod. Lastly, the mothod is applied to the turn table of a classical telescope and the residual error is about 4 arc second. The work of this paper will guide the next desgin and construction work of the thirty meter telescope tertiary mirror. 2015, Tianjin University of Technology and Springer-Verlag Berlin Heidelberg. |
文章类型 | 期刊论文 |
收录类别 | EI |
文献类型 | 期刊论文 |
条目标识符 | http://ir.ciomp.ac.cn/handle/181722/56343 |
专题 | 中科院长春光机所知识产出 |
推荐引用方式 GB/T 7714 | An, Q.-c.,J.-x. Zhang,F. Yang and J.-w. Sun. TMT tertiary mirror axis calibration with laser tracker[J]. Optoelectronics Letters,2015,11(2):84-87. |
APA | An, Q.-c.,J.-x. Zhang,&F. Yang and J.-w. Sun.(2015).TMT tertiary mirror axis calibration with laser tracker.Optoelectronics Letters,11(2),84-87. |
MLA | An, Q.-c.,et al."TMT tertiary mirror axis calibration with laser tracker".Optoelectronics Letters 11.2(2015):84-87. |
条目包含的文件 | 下载所有文件 | |||||
文件名称/大小 | 文献类型 | 版本类型 | 开放类型 | 使用许可 | ||
TMT tertiary mirror (535KB) | 期刊论文 | 作者接受稿 | 开放获取 | CC BY-NC-SA | 浏览 下载 |