Changchun Institute of Optics,Fine Mechanics and Physics,CAS
Error analysis of scanning pentaprism system in optical testing on large aperture flat mirror | |
Qi, E.; X. Luo; M. Li; L. Zheng and X. Zhang | |
2015 | |
发表期刊 | Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering
![]() |
卷号 | 44期号:2页码:639-646 |
摘要 | The scanning pentaprism system has advanta ge of simple structure, quick optical testing and providing precise measurement of low order aberrations, it is an effective method for guiding optical manufacturing of large aperture flat mirror. In order to improve the scanning pentaprism technology, this letter makes detailed analysis on the error sources include pentaprism manufacturing error, thermal effect, components'position motion, mapping error, autocollimator measurement uncertainty in the scanning pentaprism system, and derives their exact influence on the system. The analysis results show that the system's measurement uncertainty on single testing point can be about 230 nrad under current laboratory environment, and the accuracy of scanning pentaprism system is mainly limited by the measurement uncertainty of the autocollimator and the thermal effect, which providing the proceedings that should be cared for improving the system performance. This study also gives an important reference for the error analysis and precision distribution in design of the scanning pentaprism system. , 2015, Chinese Society of Astronautics. All right reserved. |
文章类型 | 期刊论文 |
收录类别 | EI |
文献类型 | 期刊论文 |
条目标识符 | http://ir.ciomp.ac.cn/handle/181722/56289 |
专题 | 中科院长春光机所知识产出 |
推荐引用方式 GB/T 7714 | Qi, E.,X. Luo,M. Li,et al. Error analysis of scanning pentaprism system in optical testing on large aperture flat mirror[J]. Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering,2015,44(2):639-646. |
APA | Qi, E.,X. Luo,M. Li,&L. Zheng and X. Zhang.(2015).Error analysis of scanning pentaprism system in optical testing on large aperture flat mirror.Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering,44(2),639-646. |
MLA | Qi, E.,et al."Error analysis of scanning pentaprism system in optical testing on large aperture flat mirror".Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering 44.2(2015):639-646. |
条目包含的文件 | 下载所有文件 | |||||
文件名称/大小 | 文献类型 | 版本类型 | 开放类型 | 使用许可 | ||
五棱镜扫描技术检测大口径平面镜的误差分析(475KB) | 期刊论文 | 作者接受稿 | 开放获取 | CC BY-NC-SA | 浏览 下载 |
个性服务 |
推荐该条目 |
保存到收藏夹 |
查看访问统计 |
导出为Endnote文件 |
谷歌学术 |
谷歌学术中相似的文章 |
[Qi, E.]的文章 |
[X. Luo]的文章 |
[M. Li]的文章 |
百度学术 |
百度学术中相似的文章 |
[Qi, E.]的文章 |
[X. Luo]的文章 |
[M. Li]的文章 |
必应学术 |
必应学术中相似的文章 |
[Qi, E.]的文章 |
[X. Luo]的文章 |
[M. Li]的文章 |
相关权益政策 |
暂无数据 |
收藏/分享 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论