Influence on the recovered spectrum caused by thermal optics effect of the collimation lens used in static Fourier transform infrared spectrometer
C. Chen; J. Q. Liang; Z. Z. Liang; J. G. Lu; Y. X. Qin; C. Tian and W. B. Wang
2015
发表期刊Acta Physica Sinica
卷号64期号:13
摘要In a stepped-mirror-based static Fourier transform infrared spectrometer, the collimation lens is located adjacent to the light source and the thermal radiation would lead to the partial temperature increase, and the refractive index of the infrared material unavoidably changes. Then the light beam passing through the collimation lens will induce a divergence angle, directly affecting the resolution of the recovered spectrum. Meanwhile, the angular divergence results in a displacement in the interference signal, making increasing difficulties in the interferogram processing and the spectrum recovery. In this paper, the distribution of temperature in different areas of the collimation lens is studied under the working condition, and the defocusing value of the collimation lens is 0.153 mm that is caused by the refractive index gradient of the infrared material along with the temperature. In addition, the divergence angle induced by defocusing is calculated, its distribution being nonuniform but symmetrical within the sample area. Moreover, the divergence angle brings about additional optical path difference, its effect on the recovered spectrum is analyzed. Compared with the ideal recovered spectrum, much noise emerges and the peak value is reduced in the real recovered spectrum. The spectrum-construction error of the real recovered spectrum is 18.72%, indicating that the recovered spectrum is seriously distorted, and the resolution at the center wavelength in the ideal recovered spectrum and the real spectrum are 4.71 cm􀀀1 and 5.57 cm􀀀1, respectively. This indicates that the spectrum resolving power is weakened. Furthermore, the reasonable temperature range is obtained by analyzing the curve of spectrum-construction error versus temperature of the collimation lens. When a spectrum-construction error of less than 5% is demanded, the temperature difference between the front len of collimation and the ambient must be less than 8 ◦C. Finally, experiments are performed using a SiC rod as the light source, and interferograms are made by four steps including dark current electric noise elimination, spatial gain correction, image signal averaging, and spectrum recovery. Results show that the spectrum-construction errors (SCE) from the cold light source and non-cold light source are 8.48% and 21.51%, respectively. Although they are all larger than the theoretical value, the SCE of cold light source decreases by 13.03% compared to cooling-free light source. Hence, it is necessary to reduced the thermal radiation influence on collimation lens from the light source. This result is helpful in solving the analogous problems.
文章类型期刊
收录类别sci
语种英语
文献类型期刊论文
条目标识符http://ir.ciomp.ac.cn/handle/181722/55933
专题中科院长春光机所知识产出
推荐引用方式
GB/T 7714
C. Chen,J. Q. Liang,Z. Z. Liang,et al. Influence on the recovered spectrum caused by thermal optics effect of the collimation lens used in static Fourier transform infrared spectrometer[J]. Acta Physica Sinica,2015,64(13).
APA C. Chen,J. Q. Liang,Z. Z. Liang,J. G. Lu,Y. X. Qin,&C. Tian and W. B. Wang.(2015).Influence on the recovered spectrum caused by thermal optics effect of the collimation lens used in static Fourier transform infrared spectrometer.Acta Physica Sinica,64(13).
MLA C. Chen,et al."Influence on the recovered spectrum caused by thermal optics effect of the collimation lens used in static Fourier transform infrared spectrometer".Acta Physica Sinica 64.13(2015).
条目包含的文件 下载所有文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
Influence on the rec(1016KB)期刊论文作者接受稿开放获取CC BY-NC-SA浏览 下载
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[C. Chen]的文章
[J. Q. Liang]的文章
[Z. Z. Liang]的文章
百度学术
百度学术中相似的文章
[C. Chen]的文章
[J. Q. Liang]的文章
[Z. Z. Liang]的文章
必应学术
必应学术中相似的文章
[C. Chen]的文章
[J. Q. Liang]的文章
[Z. Z. Liang]的文章
相关权益政策
暂无数据
收藏/分享
文件名: Influence on the recovered spectrum caused by thermal optics effect of the collimation lens used in static Fourier transform infrared spectrometer.pdf
格式: Adobe PDF
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。