摘要 | A new prototype of two-dimensional photon-counting imaging detector with induced charge WSA anode in far ultraviolet (FUV) region has been developed based on the FUV imaging spectrometer's requirements on high output count rate and spatial resolution. The detector is mainly composed of a CsI Chevron microchannel plate (MCP) stacks operating in pulse-counting mode, induced-charge wedge-strip position-sensitive anode (WSA) and correlative analog and data processing circuit. A three electrode induced-charge WSA anode with 48 mm diameter active area is designed and fabricated, and front-end analog and data collection circuit are also been developed. The space resolution for induced-charge WSA anode depends on the signal-to-noise ratio (SNR) of front-end analog circuit, while the SNR is relative to the shaping time of shaping amplifier. The longer is the shaping time, the higher is the SNR, and the lower is the maximum output rate of the front-end analog circuit. Both resolution and maximum count rate are measured for different shaping time such as 0.25, 0.5, 1, 2 and 4 ms. The measured results show that the resolution is between 4 lp/mm and 9 lp/mm, and maximum output rate is between 11 kcounts/s and 105 kcounts/s. The shaping amplifier with 0.5 ms shaping time can only completely satisfy the requirement of FUV imaging spectrometer on the spatial resolution and maximum output rate. |
收录类别 | EI |
语种 | 中文 |
文献类型 | 期刊论文 |
条目标识符 | http://ir.ciomp.ac.cn/handle/181722/44238 |
专题 | 中科院长春光机所知识产出 |
推荐引用方式 GB/T 7714 | Ni Q.. Optimization for spatial resolution and count rate of a far ultraviolet photon-counting imaging detector based on induced charge position-sensitive anode[J]. Guangxue Xuebao/Acta Optica Sinica,2014,34(8). |
APA | Ni Q..(2014).Optimization for spatial resolution and count rate of a far ultraviolet photon-counting imaging detector based on induced charge position-sensitive anode.Guangxue Xuebao/Acta Optica Sinica,34(8). |
MLA | Ni Q.."Optimization for spatial resolution and count rate of a far ultraviolet photon-counting imaging detector based on induced charge position-sensitive anode".Guangxue Xuebao/Acta Optica Sinica 34.8(2014). |
条目包含的文件 | 下载所有文件 | |||||
文件名称/大小 | 文献类型 | 版本类型 | 开放类型 | 使用许可 | ||
远紫外光子计数成像探测器分辨率及计数率的(719KB) | 开放获取 | CC BY-ND | 浏览 下载 |
个性服务 |
推荐该条目 |
保存到收藏夹 |
查看访问统计 |
导出为Endnote文件 |
谷歌学术 |
谷歌学术中相似的文章 |
[Ni Q.]的文章 |
百度学术 |
百度学术中相似的文章 |
[Ni Q.]的文章 |
必应学术 |
必应学术中相似的文章 |
[Ni Q.]的文章 |
相关权益政策 |
暂无数据 |
收藏/分享 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论