Changchun Institute of Optics,Fine Mechanics and Physics,CAS
Full-Field and Automatic Methodology of Spectral Calibration for PGP Imaging Spectrometer | |
Ci S.; Bayanheshig; Cui J. C.; Pan M. Z.; Li X. T.; Tang Y. G. | |
2014 | |
发表期刊 | Spectroscopy and Spectral Analysis |
ISSN | ISBN/1000-0593 |
卷号 | 34期号:8页码:2289-2292 |
摘要 | In order to analyze spectral data quantitatively which is obtained by prism-grating- prism imaging spectrometer, spectral calibration is required in order to determine spectral characteristics of PGP imaging spectrometer, such as the center wavelength of every spectral channel, spectral resolution and spectral bending. A spectral calibration system of full field based on collimated monochromatic light method is designed. Spherical mirror is used to provide collimated light, and a freely sliding and rotating folding mirror is adopted to change the angle of incident light in order to realize full-field and automatic calibration of imaging spectrometer. Experiments of spectral calibration have been done for PGP imaging spectrometer to obtain parameters of spectral performance, and accuracy analysis combined with the structural features of the entire spectral calibration system have been done. Analysis results indicate that spectral calibration accuracy of the calibration system reaches 0. 1 nm, and the bandwidth accuracy reaches 1. 3%. The calibration system has merits of small size, better comnionality, high precision and so on, and because of adopting the control of automation, the additional errors which are caused by human are avoided. The calibration system can be used for spectral calibration of other imaging spectrometers whose structures are similar to PGP. |
收录类别 | SCI |
语种 | 中文 |
文献类型 | 期刊论文 |
条目标识符 | http://ir.ciomp.ac.cn/handle/181722/44008 |
专题 | 中科院长春光机所知识产出 |
推荐引用方式 GB/T 7714 | Ci S.,Bayanheshig,Cui J. C.,et al. Full-Field and Automatic Methodology of Spectral Calibration for PGP Imaging Spectrometer[J]. Spectroscopy and Spectral Analysis,2014,34(8):2289-2292. |
APA | Ci S.,Bayanheshig,Cui J. C.,Pan M. Z.,Li X. T.,&Tang Y. G..(2014).Full-Field and Automatic Methodology of Spectral Calibration for PGP Imaging Spectrometer.Spectroscopy and Spectral Analysis,34(8),2289-2292. |
MLA | Ci S.,et al."Full-Field and Automatic Methodology of Spectral Calibration for PGP Imaging Spectrometer".Spectroscopy and Spectral Analysis 34.8(2014):2289-2292. |
条目包含的文件 | ||||||
文件名称/大小 | 文献类型 | 版本类型 | 开放类型 | 使用许可 | ||
PGP成像光谱仪的全视场自动化光谱定标方(225KB) | 开放获取 | CC BY-ND | 浏览 请求全文 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。