CIOMP OpenIR  > 中科院长春光机所知识产出
Effect of measured interference fringe period error on groove profile of grating masks in scanning beam interference lithography system
Jiang S.; Bayanheshig; Song Y.; Pan M.; Li W.
2014
发表期刊Guangxue Xuebao/Acta Optica Sinica
ISSNISBN/02532239
卷号34期号:4
摘要Measured interference fringe period error has a major effect on the phase stitching error in scanning beam interference lithography system. In order to make high quality grating masks which can meet the requirement of the ion beam etching, mathematical model of the relationship between measured fringe period error and dose contrast is established. Based on the photoresist nonlinearities in developing process, the developing model of grating masks made by scanning beam interference lithography system is built. According to this model, variation of groove profile with measured fringe period error is given. Experiments are done to verify this model. It shows that: measured fringe period error makes groove profile worse and varies in space domain. With a certain measured fringe period error, phase stitching error between scans is proportional to step over distance and inversely proportional to fringe period. When interference beam waist radius is 1 mm, step over distance is 0.8 mm and grating line density is 1800 gr/mm, with certain developing conditions, measured fringe period error must be less than 139 ppm to make grating masks with bottom clean without residue and groove uniform.
收录类别EI
语种英语
文献类型期刊论文
条目标识符http://ir.ciomp.ac.cn/handle/181722/43930
专题中科院长春光机所知识产出
推荐引用方式
GB/T 7714
Jiang S.,Bayanheshig,Song Y.,et al. Effect of measured interference fringe period error on groove profile of grating masks in scanning beam interference lithography system[J]. Guangxue Xuebao/Acta Optica Sinica,2014,34(4).
APA Jiang S.,Bayanheshig,Song Y.,Pan M.,&Li W..(2014).Effect of measured interference fringe period error on groove profile of grating masks in scanning beam interference lithography system.Guangxue Xuebao/Acta Optica Sinica,34(4).
MLA Jiang S.,et al."Effect of measured interference fringe period error on groove profile of grating masks in scanning beam interference lithography system".Guangxue Xuebao/Acta Optica Sinica 34.4(2014).
条目包含的文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
BOJ0812000003PlSoVr.(4154KB) 开放获取CC BY-ND浏览 下载
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Jiang S.]的文章
[Bayanheshig]的文章
[Song Y.]的文章
百度学术
百度学术中相似的文章
[Jiang S.]的文章
[Bayanheshig]的文章
[Song Y.]的文章
必应学术
必应学术中相似的文章
[Jiang S.]的文章
[Bayanheshig]的文章
[Song Y.]的文章
相关权益政策
暂无数据
收藏/分享
文件名: BOJ0812000003PlSoVr.pdf
格式: Adobe PDF
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。