CIOMP OpenIR  > 中科院长春光机所知识产出
Design and analysis for the front imaging optical system of the spatiotemporal mixed modulated Fourier transform imaging spectrometer
Wang W. C.; Liang J. Q.; Liang Z. Z.; Lu J. G.; Qin Y. X.; Tian C.; Wang W. B.
2014
发表期刊Acta Physica Sinica
ISSNISBN/1000-3290
卷号63期号:10页码:8
摘要In order to satisfy the application requirements of the large flux and the high stability for the infrared imaging spectrometer, we propose a new type of static no-slit spatiotemporally mixed modulated Fourier transform imaging spectrometer based on the multi-level micro-mirrors. The working process and the generation manner of optical path difference of the system are analyzed. The front imaging system, as an important component of the imaging spectrometer, determines the distribution of the optical path difference, and its performance directly affects the image quality of target object. According to the generation manner of optical path difference of the system, the front imaging system for the telecentric structure in the image space is analyzed and designed. The athermalization design research is carried out by means of the passive optical elimination thermal difference. The result shows that the modulation transfer function curve of each field reaches the diffraction limit in a temperature range of -20-60 degrees C. The front imaging optical system has a good imaging quality in the total step height of the multi-step micro-mirrors. At different temperatures, the maximum incident angle on the image surface is less than 0.02 degrees for the principal ray of each field.
收录类别SCI ; EI
语种中文
文献类型期刊论文
条目标识符http://ir.ciomp.ac.cn/handle/181722/43829
专题中科院长春光机所知识产出
推荐引用方式
GB/T 7714
Wang W. C.,Liang J. Q.,Liang Z. Z.,et al. Design and analysis for the front imaging optical system of the spatiotemporal mixed modulated Fourier transform imaging spectrometer[J]. Acta Physica Sinica,2014,63(10):8.
APA Wang W. C..,Liang J. Q..,Liang Z. Z..,Lu J. G..,Qin Y. X..,...&Wang W. B..(2014).Design and analysis for the front imaging optical system of the spatiotemporal mixed modulated Fourier transform imaging spectrometer.Acta Physica Sinica,63(10),8.
MLA Wang W. C.,et al."Design and analysis for the front imaging optical system of the spatiotemporal mixed modulated Fourier transform imaging spectrometer".Acta Physica Sinica 63.10(2014):8.
条目包含的文件 下载所有文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
时空联合调制成像光谱仪前置成像系统分析与(1777KB) 开放获取CC BY-ND浏览 下载
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Wang W. C.]的文章
[Liang J. Q.]的文章
[Liang Z. Z.]的文章
百度学术
百度学术中相似的文章
[Wang W. C.]的文章
[Liang J. Q.]的文章
[Liang Z. Z.]的文章
必应学术
必应学术中相似的文章
[Wang W. C.]的文章
[Liang J. Q.]的文章
[Liang Z. Z.]的文章
相关权益政策
暂无数据
收藏/分享
文件名: 时空联合调制成像光谱仪前置成像系统分析与设计.pdf
格式: Adobe PDF
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。