Changchun Institute of Optics,Fine Mechanics and Physics,CAS
Design of High-Efficiency Double Compound Parabolic Concentrator System in Near Infrared Noninvasive Biochemical Analysis | |
Gao J.![]() | |
2013 | |
发表期刊 | Spectroscopy and Spectral Analysis
![]() |
ISSN | ISBN/1000-0593 |
卷号 | 33期号:5 |
摘要 | High signal-to-noise ratio (SNR) of system is necessary to obtain accurate blood components in near infrared noninvasive biochemical analysis. In order to improve SNR of analytical system, high-efficiency double compound parabolic concentrator (DCPC) system was researched, which was aimed at increasing light utilization efficiency. Firstly, with the request of collection efficiency in near infrared noninvasive biochemical analysis, the characteristic of emergent rays through compound parabolic concentrator (CPC) was analyzed. Then the maximum focusing angle range of the first stage CPC was determined. Secondly, the light utilization efficiency of truncated type was compared with standard DCPC, thus the best structure parameters of DCPC system were optimized. Lastly, combined with optical parameters of skin tissue, calculations were operated when incident wavelength is 1 000 nm. The light utilization efficiency of DCPC system, CPC-focusing mirror system, and non-optical collecting system was calculated. The results show that the light utilization efficiency of the three optical systems is 1. 46%, 0. 84% and 0. 26% respectively. So DCPC system enhances collecting ability for human diffuse reflection light, and helps improve SNR of noninvasive biochemical analysis system and overall analysis accuracy effectively. |
收录类别 | SCI |
语种 | 中文 |
文献类型 | 期刊论文 |
条目标识符 | http://ir.ciomp.ac.cn/handle/181722/40607 |
专题 | 中科院长春光机所知识产出 |
推荐引用方式 GB/T 7714 | Gao J.,Lu Q. P.,Peng Z. Q.,et al. Design of High-Efficiency Double Compound Parabolic Concentrator System in Near Infrared Noninvasive Biochemical Analysis[J]. Spectroscopy and Spectral Analysis,2013,33(5). |
APA | Gao J.,Lu Q. P.,Peng Z. Q.,Ding H. Q.,&Gao H. Z..(2013).Design of High-Efficiency Double Compound Parabolic Concentrator System in Near Infrared Noninvasive Biochemical Analysis.Spectroscopy and Spectral Analysis,33(5). |
MLA | Gao J.,et al."Design of High-Efficiency Double Compound Parabolic Concentrator System in Near Infrared Noninvasive Biochemical Analysis".Spectroscopy and Spectral Analysis 33.5(2013). |
条目包含的文件 | 下载所有文件 | |||||
文件名称/大小 | 文献类型 | 版本类型 | 开放类型 | 使用许可 | ||
近红外无创生化分析中高效双复合抛物面聚光(642KB) | 开放获取 | CC BY-NC-ND | 浏览 下载 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。