摘要 | Oxygen plasma technology was applied to obtain the hydrophilic poly(dimethylsiloxane) (PDMS) surface. The effects of treatment time, power and oxygen flow in oxygen plasma on POMS surface hydrophilicity have been tested. Contact angle measurements and X-ray photoelectron spectroscopy (XPS) were used to estimate the effect and stability of the modified surfaces. Experiments show that the contact angle is 72 degrees after ageing 700 hours by oxygen plasma treatment, and XPS indicates that the improvement of surface hydrophilicity mainly due to the increase of the polar component of the surface. The mechanism of the PDMS surface modification was discussed. |
收录类别 | SCI |
语种 | 中文 |
文献类型 | 期刊论文 |
条目标识符 | http://ir.ciomp.ac.cn/handle/181722/25734 |
专题 | 中科院长春光机所知识产出 |
推荐引用方式 GB/T 7714 | Li Y. G.,Zhang P.,Wu Y. H.,et al. Studies on the hydrophilicity of poly(dimethylsiloxane) surface[J]. Chinese Journal of Analytical Chemistry,2006,34(4):508-510. |
APA | Li Y. G.,Zhang P.,Wu Y. H.,&Xuan M..(2006).Studies on the hydrophilicity of poly(dimethylsiloxane) surface.Chinese Journal of Analytical Chemistry,34(4),508-510. |
MLA | Li Y. G.,et al."Studies on the hydrophilicity of poly(dimethylsiloxane) surface".Chinese Journal of Analytical Chemistry 34.4(2006):508-510. |
条目包含的文件 | 下载所有文件 | |||||
文件名称/大小 | 文献类型 | 版本类型 | 开放类型 | 使用许可 | ||
聚二甲基硅氧烷表面亲水性的研究.caj(79KB) | 开放获取 | -- | 浏览 下载 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论