摘要Accurate and real-time temperature detection is an urgent requirement in photothermal therapy (PTT). In this work, the CaSc2O4: Nd3+ nanorod with an average length of 150 nm has been determined to be an outstanding optical thermometer based on the fluorescence intensity ratio (FIR) of thermally coupled Stark sublevels of Nd3+: 4F3/2 -> 4I11/2 transition, of which the excitation and emission wavelength are located in the first and second biological window respectively, resulting in an 8 mm penetration depth in the biological tissues. The maximal absolute sensitivity and relative sensitivity as well as the minimal temperature resolution of the present sample is 0.0008 K-1, 0.0018 K-1 and 0.19 K respectively, which is superior to the vast majority of the same type ther-mometers. Besides that, the nanorods show a 7 K temperature increment after 180 s' 808 nm-laser radiation, revealing its photothermal conversion capacity thanks to the considerable nonradiative relaxation processes among the metastable energy levels of Nd3+. These results indicate that Nd3+ single-doped CaSc2O4 nanorods can be utilized as the optical thermometer in the deep-tissue PTT process for real-time thermometry along with the function of light-to-heat conversion.
DOI10.1016/j.ceramint.2022.12.260
URL查看原文
收录类别sci ; ei
语种英语
引用统计
文献类型期刊论文
条目标识符http://ir.ciomp.ac.cn/handle/181722/68549
专题中国科学院长春光学精密机械与物理研究所
推荐引用方式
GB/T 7714
G. T. Xiang, M. L. Yang, Y. X. Ding, H. X. Wu, L. Yao, Y. J. Wang, X. J. Zhou, L. Li, L. Ma, X. J. Wang and J. H. Zhang. Ratiometric nanothermometer CaSc2O4: Nd3+ operating in biological window for deep-tissue photothermal therapy[J]. Ceramics International,2023,49(9):13816-13822.
APA G. T. Xiang, M. L. Yang, Y. X. Ding, H. X. Wu, L. Yao, Y. J. Wang, X. J. Zhou, L. Li, L. Ma, X. J. Wang and J. H. Zhang.(2023).Ratiometric nanothermometer CaSc2O4: Nd3+ operating in biological window for deep-tissue photothermal therapy.Ceramics International,49(9),13816-13822.
MLA G. T. Xiang, M. L. Yang, Y. X. Ding, H. X. Wu, L. Yao, Y. J. Wang, X. J. Zhou, L. Li, L. Ma, X. J. Wang and J. H. Zhang."Ratiometric nanothermometer CaSc2O4: Nd3+ operating in biological window for deep-tissue photothermal therapy".Ceramics International 49.9(2023):13816-13822.
条目包含的文件 下载所有文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
Ratiometric nanother(4543KB)期刊论文出版稿开放获取CC BY-NC-SA浏览 下载
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[G. T. Xiang, M. L. Yang, Y. X. Ding, H. X. Wu, L. Yao, Y. J. Wang, X. J. Zhou, L. Li, L. Ma, X. J. Wang and J. H. Zhang]的文章
百度学术
百度学术中相似的文章
[G. T. Xiang, M. L. Yang, Y. X. Ding, H. X. Wu, L. Yao, Y. J. Wang, X. J. Zhou, L. Li, L. Ma, X. J. Wang and J. H. Zhang]的文章
必应学术
必应学术中相似的文章
[G. T. Xiang, M. L. Yang, Y. X. Ding, H. X. Wu, L. Yao, Y. J. Wang, X. J. Zhou, L. Li, L. Ma, X. J. Wang and J. H. Zhang]的文章
相关权益政策
暂无数据
收藏/分享
文件名: Ratiometric nanothermometer CaSc2O4 Nd3 operating in biological window for deep-tissue photothermal therapy.pdf
格式: Adobe PDF
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。