CIOMP OpenIR
Comparative Study on Hyperspectral Inversion Models of Water Quality Parameters
Y. B. Zou, Z. Y. Ma, Q. B. Jiao, L. Xu, J. Pei, Y. H. Li, Y. X. Xu, J. H. Zhang, H. Li, L. Yang, S. Q. Liu, W. Zhang and X. Tan
2023
发表期刊Spectroscopy and Spectral Analysis
ISSN1000-0593
卷号43期号:3页码:949-954
摘要Water is a basic need for life and health. Human production and life are inseparable from water. Excessive nitrogen and phosphorus in the water body lead to excess nutrients, resulting in eutrophication of the water body, and then the deterioration of water quality has a wide-ranging impact. The application of hyperspectral remote sensing in the inland water quality monitoring field is becoming more and more extensive. Based on this research, to reduce the influence of outdoor water body-specific factors, this study builds an experimental laboratory system by simulating external conditions in the laboratory. According to national emission standards, this study prepares 40 sodium phosphate standard solutions with different concentration gradients in the concentration range of 0 similar to 2. 5 mg center dot L-1 and 40 different concentration gradient ammonium chloride standard solutions in the concentration range of 0 similar to 20 mg center dot L (1). After obtaining hyperspectral images of all standard solutions, The spectral responses of water quality parameters total phosphorus and total nitrogen were analyzed. This study finds the sensitive bands corresponding to total phosphorus and total nitrogen at around 420, 720 nm and around 410 nm. Building a hyperspectral water quality inversion dataset using Principal Component Analysis (PCA). By preprocessing hyperspectral image radiometric calibration, Savitzky-Golay filtering (SG filtering), and using the BP artificial neural network method to construct a laboratory hyperspectral water quality inversion model. The coefficient of determination of the constructed laboratory hyperspectral total phosphorus inversion model is 0. 980 2, and the determination coefficient of the laboratory hyperspectral total nitrogen inversion model is 0. 860 2. Taking an indoor river in Yixing, Jiangsu as the research object. The model is applied to the outdoor hyperspectral image data obtained by the outdoor UAV equipped with the hyperspectral imaging system. The inversion accuracies of the mean concentrations of total phosphorus and total nitrogen are 95. 00%0 and 93. 52% respectively. The outdoor hyperspectral water quality inversion model constructed by using the traditional method to directly draw water from the observation points of the river to be tested the average values of total phosphorus and total nitrogen concentrations obtained at the same five points with an inversion accuracy of 86. 87% and 86. 48%. This study compares the inversion results of the two groups. It is found that the inversion accuracy of 90% of the spectral inversion results obtained by the laboratory hyperspectral water quality inversion model constructed in this study is slightly higher than that of the outdoor water quality inversion model. It is confirmed that this study can effectively predict the content of total phosphorus and total nitrogen in the river to be measured, and can also provide certain technical support for the hyperspectral remote sensing inversion of total phosphorus and total nitrogen in the water.
DOI10.3964/j.issn.1000-0593(2023)03-0949-06
URL查看原文
收录类别sci ; ei
语种英语
引用统计
被引频次:1[WOS]   [WOS记录]     [WOS相关记录]
文献类型期刊论文
条目标识符http://ir.ciomp.ac.cn/handle/181722/68295
专题中国科学院长春光学精密机械与物理研究所
推荐引用方式
GB/T 7714
Y. B. Zou, Z. Y. Ma, Q. B. Jiao, L. Xu, J. Pei, Y. H. Li, Y. X. Xu, J. H. Zhang, H. Li, L. Yang, S. Q. Liu, W. Zhang and X. Tan. Comparative Study on Hyperspectral Inversion Models of Water Quality Parameters[J]. Spectroscopy and Spectral Analysis,2023,43(3):949-954.
APA Y. B. Zou, Z. Y. Ma, Q. B. Jiao, L. Xu, J. Pei, Y. H. Li, Y. X. Xu, J. H. Zhang, H. Li, L. Yang, S. Q. Liu, W. Zhang and X. Tan.(2023).Comparative Study on Hyperspectral Inversion Models of Water Quality Parameters.Spectroscopy and Spectral Analysis,43(3),949-954.
MLA Y. B. Zou, Z. Y. Ma, Q. B. Jiao, L. Xu, J. Pei, Y. H. Li, Y. X. Xu, J. H. Zhang, H. Li, L. Yang, S. Q. Liu, W. Zhang and X. Tan."Comparative Study on Hyperspectral Inversion Models of Water Quality Parameters".Spectroscopy and Spectral Analysis 43.3(2023):949-954.
条目包含的文件 下载所有文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
Comparative Study on(21534KB)期刊论文出版稿开放获取CC BY-NC-SA浏览 下载
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Y. B. Zou, Z. Y. Ma, Q. B. Jiao, L. Xu, J. Pei, Y. H. Li, Y. X. Xu, J. H. Zhang, H. Li, L. Yang, S. Q. Liu, W. Zhang and X. Tan]的文章
百度学术
百度学术中相似的文章
[Y. B. Zou, Z. Y. Ma, Q. B. Jiao, L. Xu, J. Pei, Y. H. Li, Y. X. Xu, J. H. Zhang, H. Li, L. Yang, S. Q. Liu, W. Zhang and X. Tan]的文章
必应学术
必应学术中相似的文章
[Y. B. Zou, Z. Y. Ma, Q. B. Jiao, L. Xu, J. Pei, Y. H. Li, Y. X. Xu, J. H. Zhang, H. Li, L. Yang, S. Q. Liu, W. Zhang and X. Tan]的文章
相关权益政策
暂无数据
收藏/分享
文件名: Comparative Study on Hyperspectral Inversion Models of Water Quality Parameters.pdf
格式: Adobe PDF
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。