CIOMP OpenIR
An ultrahigh sensitivity acoustic sensor system for weak signal detection based on an ultrahigh- Q CaF2 resonator
T. Xing, E. B. Xing, T. Jia, J. L. Li, J. M. Rong, L. Li, S. C. Tian, Y. R. Zhou, W. Y. Liu, J. Tang and J. Liu
2023
发表期刊Microsystems & Nanoengineering
ISSN2055-7434
卷号9期号:1页码:11
摘要Acoustic sensors with ultrahigh sensitivity, broadband response, and high resolution are essential for high-precision nondestructive weak signal detection technology. In this paper, based on the size effect of an ultrahigh-quality (Q) calcium fluoride (CaF2) resonator, a weak acoustic signal is detected by the dispersive response regime in which an acoustic, elastic wave modulates the geometry and is converted to a resonance frequency shift. Through the structural design of the resonator, the sensitivity reaches 11.54 V/Pa at 10 kHz in the experiment. To our knowledge, the result is higher than that of other optical resonator acoustic sensors. We further detected a weak signal as low as 9.4 mu Pa/Hz(1/2), which greatly improved the detection resolution. With a good directionality of 36.4 dB and a broadband frequency response range of 20 Hz-20 kHz, the CaF2 resonator acoustic sensing system can not only acquire and reconstruct speech signals over a long distance but also accurately identify and separate multiple voices in noisy environments. This system shows high performance in weak sound detection, sound source localization, sleep monitoring, and many other voice interaction applications.
DOI10.1038/s41378-023-00540-0
URL查看原文
收录类别sci ; ei
语种英语
引用统计
文献类型期刊论文
条目标识符http://ir.ciomp.ac.cn/handle/181722/68051
专题中国科学院长春光学精密机械与物理研究所
推荐引用方式
GB/T 7714
T. Xing, E. B. Xing, T. Jia, J. L. Li, J. M. Rong, L. Li, S. C. Tian, Y. R. Zhou, W. Y. Liu, J. Tang and J. Liu. An ultrahigh sensitivity acoustic sensor system for weak signal detection based on an ultrahigh- Q CaF2 resonator[J]. Microsystems & Nanoengineering,2023,9(1):11.
APA T. Xing, E. B. Xing, T. Jia, J. L. Li, J. M. Rong, L. Li, S. C. Tian, Y. R. Zhou, W. Y. Liu, J. Tang and J. Liu.(2023).An ultrahigh sensitivity acoustic sensor system for weak signal detection based on an ultrahigh- Q CaF2 resonator.Microsystems & Nanoengineering,9(1),11.
MLA T. Xing, E. B. Xing, T. Jia, J. L. Li, J. M. Rong, L. Li, S. C. Tian, Y. R. Zhou, W. Y. Liu, J. Tang and J. Liu."An ultrahigh sensitivity acoustic sensor system for weak signal detection based on an ultrahigh- Q CaF2 resonator".Microsystems & Nanoengineering 9.1(2023):11.
条目包含的文件 下载所有文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
An ultrahigh sensiti(2569KB)期刊论文出版稿开放获取CC BY-NC-SA浏览 下载
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[T. Xing, E. B. Xing, T. Jia, J. L. Li, J. M. Rong, L. Li, S. C. Tian, Y. R. Zhou, W. Y. Liu, J. Tang and J. Liu]的文章
百度学术
百度学术中相似的文章
[T. Xing, E. B. Xing, T. Jia, J. L. Li, J. M. Rong, L. Li, S. C. Tian, Y. R. Zhou, W. Y. Liu, J. Tang and J. Liu]的文章
必应学术
必应学术中相似的文章
[T. Xing, E. B. Xing, T. Jia, J. L. Li, J. M. Rong, L. Li, S. C. Tian, Y. R. Zhou, W. Y. Liu, J. Tang and J. Liu]的文章
相关权益政策
暂无数据
收藏/分享
文件名: An ultrahigh sensitivity acoustic sensor syste.pdf
格式: Adobe PDF
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。