摘要Objective Crustal movement will discharge CO2 and other gases to the surface, and the surface concentration of CO2 near the fault zone will be abnormal before the earthquake. High-precision measurement of CO2 gas near the seismic zone can provide important help for the analysis of earthquake precursors. At present, the main methods for measuring CO2 concentration include non-dispersive infrared analysis technology, electrochemical technology, chromatographic analysis technology, etc. However, the above methods generally have the disadvantages of being easily disturbed by its background gas, low accuracy, and unable to achieve real-time monitoring. Tunable diode laser absorption spectroscopy (TDLAS) technology has the advantages of not being disturbed by its background gas, high accuracy, and real-time monitoring. In recent years, it has become a research hotspot at home and abroad and has been widely used in the field of gas detection. In this paper, a high-precision CO2 detection system is developed by using tunable diode laser absorption spectroscopy technology. Methods In this paper, a high-precision CO2 detection system for seismic monitoring is established. The tunable diode laser absorption spectroscopy technology is adopted, and the wave number 4 978.202 cm−1 is selected as the absorption spectral line of the CO2 detection system (Fig.1). A multi-channel unit with an effective optical path of 40 m is adopted, and STM32 is used as the control equipment and data processing core equipment (Fig.2). For the detector noise and optical interference fringe noise in the system, Kalman-wavelet analysis algorithm is used to filter and improve the system. Results and Discussions The system uses Kalman-wavelet analysis method to eliminate the influence of detector noise and optical fringe interference. The experiment shows that the second harmonic signal to noise ratio of the system at 50 ppmv CO2 concentration is 2.06 times higher than that before filtering (Fig.3). Under different CO2 concentrations (50 ppmv, 300 ppmv, 1 000 ppmv, 4 000 ppmv, 8 000 ppmv), the system error is 2.57%-2.66% (Fig.4). When the system measures CO2 at 4 000 ppmv concentration, the detection precision reaches 20.9 ppmv (Fig.5). According to Allan variance analysis, the method detection limit (MDL) corresponding to the integration time of about 61s is 5.2 ppmv (Fig.6), which realizes the high-precision measurement of CO2 gas. Conclusions This paper develops a high-precision CO2 detection system for seismic monitoring. The system adjusts the current injected into the DFB laser to make its output central wavelength at 2 008 nm and serve as the detection light source of CO2. In order to improve the lower detection limit of CO2 gas concentration, the system uses a self-developed cylindrical mirror multi-pass cell with an effective optical path of 40 m. The multi-pass cell can work stably in the temperature range of 0-40 ℃ and the pressure range of 1.333-101.325 kPa to ensure the reliability of the system in the field measurement process. The system control TEC realizes the temperature control of the controlled object, and the control precision of the temperature control system in the laboratory can reach 0.01 ℃. The Kalman-wavelet analysis algorithm is used to filter the system noise, and the frequency of optical fringe interference in the frequency domain is similar to that of cosine wave in the time domain, so as to separate it and remove the optical fringe interference. The experimental results show that the accuracy, precision and the method detection limit of the system are improved after filtering. The system combined with this method can make the geochemical gas measurement have a broader application prospect and provide important help for the accurate analysis of earthquake precursors. © 2023 Chinese Society of Astronautics. All rights reserved.
DOI10.3788/IRLA20210828
URL查看原文
收录类别ei
引用统计
文献类型期刊论文
条目标识符http://ir.ciomp.ac.cn/handle/181722/67610
专题中国科学院长春光学精密机械与物理研究所
推荐引用方式
GB/T 7714
H. Li,H. Piao,P. Wang,et al. Development of high precision CO2 detection system based on near infrared absorption spectroscopy[J]. Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering,2023,52(3).
APA H. Li.,H. Piao.,P. Wang.,Y. Jiang.,Z. Li.,...&B. Wang and M. Li.(2023).Development of high precision CO2 detection system based on near infrared absorption spectroscopy.Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering,52(3).
MLA H. Li,et al."Development of high precision CO2 detection system based on near infrared absorption spectroscopy".Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering 52.3(2023).
条目包含的文件 下载所有文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
Development of high (1714KB)期刊论文出版稿开放获取CC BY-NC-SA浏览 下载
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[H. Li]的文章
[H. Piao]的文章
[P. Wang]的文章
百度学术
百度学术中相似的文章
[H. Li]的文章
[H. Piao]的文章
[P. Wang]的文章
必应学术
必应学术中相似的文章
[H. Li]的文章
[H. Piao]的文章
[P. Wang]的文章
相关权益政策
暂无数据
收藏/分享
文件名: Development of high precision CO2 detection system based on near infrared absorption spectroscopy.pdf
格式: Adobe PDF
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。