CIOMP OpenIR
Research on an active control method of double crystal monochromator with disturbance observer
Y. Bai, X. Gong, Q. Lu, S. Li, Y. Song, Z. Peng and Z. Zhang
2023
发表期刊Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
ISSN01689002
卷号1057
摘要The double crystal monochromator (DCM) is the core equipment of high flux and high monochromatic light on the synchrotron beamline, which directly affects the performance of the synchrotron hard X-ray beamline in terms of stability. To meet the requirements for the stability of the nano-radian magnitude of the DCM for the 4th-generation synchrotron light source, this paper presents a method to suppress the primary resonance of the system using an integral lead compensation notch filter and eliminate the higher-order positive and negative resonance peaks with a dual second-order notch filter. The bandwidth of the DCM system is enhanced to meet the system speed requirements. Meanwhile, the mechanical coupling is considered equivalent to the system's internal disturbance. The disturbance observer is designed to ensure the stability and dynamic performance of the DCM system. The simulation results show that after correction by the integral lead compensation notch filter and the dual second-order notch filter, the system bandwidth can reach 308Hz while maintaining a phase margin of approximately 25°. Furthermore, the stability of DCM can reach an RMS of 0.139 nrad, 16.610 nrad, and 1.431 nm in the Pitch, Roll, and Gap direction, respectively, with the help of a disturbance observer. The paper proposes a method to develop stable DCMs in 4th-generation synchrotron radiation facilities while improving the X-ray beamline performance. © 2023
DOI10.1016/j.nima.2023.168729
URL查看原文
收录类别sci ; ei
引用统计
被引频次:1[WOS]   [WOS记录]     [WOS相关记录]
文献类型期刊论文
条目标识符http://ir.ciomp.ac.cn/handle/181722/67340
专题中国科学院长春光学精密机械与物理研究所
推荐引用方式
GB/T 7714
Y. Bai, X. Gong, Q. Lu, S. Li, Y. Song, Z. Peng and Z. Zhang. Research on an active control method of double crystal monochromator with disturbance observer[J]. Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment,2023,1057.
APA Y. Bai, X. Gong, Q. Lu, S. Li, Y. Song, Z. Peng and Z. Zhang.(2023).Research on an active control method of double crystal monochromator with disturbance observer.Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment,1057.
MLA Y. Bai, X. Gong, Q. Lu, S. Li, Y. Song, Z. Peng and Z. Zhang."Research on an active control method of double crystal monochromator with disturbance observer".Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 1057(2023).
条目包含的文件 下载所有文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
Research on an activ(9148KB)期刊论文出版稿开放获取CC BY-NC-SA浏览 下载
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Y. Bai, X. Gong, Q. Lu, S. Li, Y. Song, Z. Peng and Z. Zhang]的文章
百度学术
百度学术中相似的文章
[Y. Bai, X. Gong, Q. Lu, S. Li, Y. Song, Z. Peng and Z. Zhang]的文章
必应学术
必应学术中相似的文章
[Y. Bai, X. Gong, Q. Lu, S. Li, Y. Song, Z. Peng and Z. Zhang]的文章
相关权益政策
暂无数据
收藏/分享
文件名: Research on an active control method of double crystal monochromator with disturbance observer.pdf
格式: Adobe PDF
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。