Changchun Institute of Optics,Fine Mechanics and Physics,CAS
Evaluation of aerosol microphysical, optical and radiative properties measured with a multiwavelength photometer | |
Y. Zheng; H. Z. Che; Y. P. Wang; X. G. Xia; X. Q. Hu; X. C. Zhang; J. Zhu; J. B. Zhu; H. J. Zhao; L. Li; K. Gui and X. Y. Zhang | |
2022 | |
发表期刊 | Atmospheric Measurement Techniques |
ISSN | 1867-1381 |
卷号 | 15期号:7页码:2139-2158 |
摘要 | An evaluation of aerosol microphysical, optical and radiative properties measured with a multiwavelength photometer named CW193 was performed in this study. The instrument has a highly integrated design, smart control performance and is composed of three parts (the optical head, robotic drive platform and stents system). Based on synchronous measurements, the CW193 products were validated using reference data from the AERONET CE318 photometer. The results show that the raw digital counts from CW193 agree well with the counts from AERONET (R > 0.989), with daily average triplets of around 1.2 % to 3.0 % for the ultraviolet band and less than 2.0 % for the visible and infrared bands. Good aerosol optical depth agreement (R > 0.997, 100 % within expected error) and root mean square error (RMSE) values ranging from 0.006 (for the 870 nm band) to 0.016 (for the 440 nm band) were obtained, with the relative mean bias (RMB) ranging from 0.922 to 1.112 and the aerosol optical depth bias within +/- 0.04. The maximum deviation of the peak value for fine-mode particles varied from about 8.9 % to 77.6 %, whereas the variation for coarse-mode particles was about 13.1 % to 29.1 %. The deviation vari ations of the single scattering albedo were approximately 0.1 %-1.8 %, 0.6 %-1.9 %, 0.1 %-2.6 % and 0.8 %-3.5 % for the 440, 675, 870 and 1020 nm bands, respectively. For the aerosol direct radiative forcing, deviations of approximately 4.8 %-12.3 % were obtained at the earth's surface and 5.4 %-15.9 % for the top of the atmosphere. In addition, the water vapor retrievals showed satisfactory accuracy, characterized by a high R value (similar to 0.997), a small RMSE (similar to 0.020) and a good expected error distribution (100 % within expected error). The water vapor RMB was about 0.979, and the biases mostly varied within +/- 0.04, whereas the mean values were concentrated within +/- 0.02. |
DOI | 10.5194/amt-15-2139-2022 |
URL | 查看原文 |
收录类别 | sci |
语种 | 英语 |
引用统计 | |
文献类型 | 期刊论文 |
条目标识符 | http://ir.ciomp.ac.cn/handle/181722/67302 |
专题 | 中国科学院长春光学精密机械与物理研究所 |
推荐引用方式 GB/T 7714 | Y. Zheng,H. Z. Che,Y. P. Wang,et al. Evaluation of aerosol microphysical, optical and radiative properties measured with a multiwavelength photometer[J]. Atmospheric Measurement Techniques,2022,15(7):2139-2158. |
APA | Y. Zheng.,H. Z. Che.,Y. P. Wang.,X. G. Xia.,X. Q. Hu.,...&K. Gui and X. Y. Zhang.(2022).Evaluation of aerosol microphysical, optical and radiative properties measured with a multiwavelength photometer.Atmospheric Measurement Techniques,15(7),2139-2158. |
MLA | Y. Zheng,et al."Evaluation of aerosol microphysical, optical and radiative properties measured with a multiwavelength photometer".Atmospheric Measurement Techniques 15.7(2022):2139-2158. |
条目包含的文件 | 下载所有文件 | |||||
文件名称/大小 | 文献类型 | 版本类型 | 开放类型 | 使用许可 | ||
Evaluation of aeroso(7024KB) | 期刊论文 | 出版稿 | 开放获取 | CC BY-NC-SA | 浏览 下载 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论