摘要 | Subaperture stitching interferometry (SSI) is an essential method for the map testing of large-aperture optical components. The surface map of a reference surface is a typical error source. In this study, we propose a hybrid self-calibration method to eliminate the reference surface error in SSI by combining the modified shift-rotation method and the maximum likelihood method. The traditional shift-rotation method is a general full-aperture absolute interferometric measurement that can retain localized irregularities. The shift-rotation operations are leveraged to generate a couple of subapertures covering the surface under test, whereby a ring of subapertures and a central subaperture are acquired by rotations and a lateral shift, respectively. The modified shift-rotation method is proposed to obtain the rotationally asymmetric components of the test surface in the ring of subapertures. The same components within the central subaperture are retrieved using the maximum likelihood method. Then, the rotationally symmetric components of the test surface are acquired using the least squares method, utilizing the measured data before and after the shift. Reference surface maps are sufficiently eliminated from the measured data. High-frequency components of the test surface are also retained, which engender high-accuracy SSI. Simulations are conducted to verify the proposed method. The positioning errors of the proposed method are analysed and discussed. Subaperture testing experiments of a 100-mm aperture flat are performed and compared with full-aperture absolute measurement results. The stitched errors with 0.018 2 PV and 0.003 2 RMS are obtained. |
DOI | 10.1016/j.optcom.2022.128278 |
URL | 查看原文 |
收录类别 | sci ; ei |
语种 | 英语 |
引用统计 | |
文献类型 | 期刊论文 |
条目标识符 | http://ir.ciomp.ac.cn/handle/181722/66738 |
专题 | 中国科学院长春光学精密机械与物理研究所 |
推荐引用方式 GB/T 7714 | W. J. Liu,Z. S. Gao,R. Y. Wang,et al. Hybrid self-calibration method for reference surface elimination in subaperture stitching interferometry[J]. Optics Communications,2022,517:9. |
APA | W. J. Liu.,Z. S. Gao.,R. Y. Wang.,X. Y. Che.,L. J. Wang.,...&Z. Y. Guo and Q. Yuan.(2022).Hybrid self-calibration method for reference surface elimination in subaperture stitching interferometry.Optics Communications,517,9. |
MLA | W. J. Liu,et al."Hybrid self-calibration method for reference surface elimination in subaperture stitching interferometry".Optics Communications 517(2022):9. |
条目包含的文件 | 下载所有文件 | |||||
文件名称/大小 | 文献类型 | 版本类型 | 开放类型 | 使用许可 | ||
Hybrid self-calibrat(3668KB) | 期刊论文 | 出版稿 | 开放获取 | CC BY-NC-SA | 浏览 下载 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论