CIOMP OpenIR
A High-Resolution MIR Echelle Grating Spectrometer with a Three-Mirror Anastigmatic System
Q. Y. Wang; H. H. Shen; W. Q. Liu and P. Z. Dai
2022
发表期刊Applied Sciences-Basel
卷号12期号:16页码:14
摘要With the emergence of high-performance infrared detectors and the latest progress in grating manufacturing technology, high-resolution and high-sensitivity infrared spectrometers provide new methods for application to many fields, including astronomy and remote sensing detection. Spectral detection has attracted considerable attention due to its advantages of noncontact and stability. To obtain the detailed features of the missile's tail flame spectrum, traditional plane reflection gratings are used as the main dispersive element; however, the instrument's volume will increase with increasing resolution, which is not conducive to remote sensing detection from airborne platforms. Such spectrometers cannot meet high-resolution spectroscopy requirements. To address this problem, this paper proposes an immersion echelle spectrometer combined with a three-mirror astigmatism optical system. High resolution and compact size were achieved. In this paper, a small high-resolution infrared echelle spectrometer optical system was created by combining an off-axis three-mirror anti-astigmatism system, a Littrow structure, and a concave grating Wadsworth imaging device. The optical system operated in the 3.7-4.8 mu m band; the echelle grating worked under quasi-Littrow conditions, while the concave grating was used for auxiliary dispersion to separate overlapping orders. The resolution of the optical system in the entire working band was 23,000-45,000. The optical plane size of the spectrometer was around 360 mm x 165 mm. The results show that the Mid-IR echelle spectrometer achieved high spectral resolution, better than 0.25 cm(-1), meeting missile tail flame detection requirements. This device has the potential for real-time long-range target detection when warheads are destroyed. While this study focuses on the mid-wave infrared band, its approach can also be extended to other infrared bands.
DOI10.3390/app12168013
URL查看原文
收录类别sci
语种英语
引用统计
被引频次:2[WOS]   [WOS记录]     [WOS相关记录]
文献类型期刊论文
条目标识符http://ir.ciomp.ac.cn/handle/181722/66732
专题中国科学院长春光学精密机械与物理研究所
推荐引用方式
GB/T 7714
Q. Y. Wang,H. H. Shen,W. Q. Liu and P. Z. Dai. A High-Resolution MIR Echelle Grating Spectrometer with a Three-Mirror Anastigmatic System[J]. Applied Sciences-Basel,2022,12(16):14.
APA Q. Y. Wang,H. H. Shen,&W. Q. Liu and P. Z. Dai.(2022).A High-Resolution MIR Echelle Grating Spectrometer with a Three-Mirror Anastigmatic System.Applied Sciences-Basel,12(16),14.
MLA Q. Y. Wang,et al."A High-Resolution MIR Echelle Grating Spectrometer with a Three-Mirror Anastigmatic System".Applied Sciences-Basel 12.16(2022):14.
条目包含的文件 下载所有文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
A High-Resolution MI(5775KB)期刊论文出版稿开放获取CC BY-NC-SA浏览 下载
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Q. Y. Wang]的文章
[H. H. Shen]的文章
[W. Q. Liu and P. Z. Dai]的文章
百度学术
百度学术中相似的文章
[Q. Y. Wang]的文章
[H. H. Shen]的文章
[W. Q. Liu and P. Z. Dai]的文章
必应学术
必应学术中相似的文章
[Q. Y. Wang]的文章
[H. H. Shen]的文章
[W. Q. Liu and P. Z. Dai]的文章
相关权益政策
暂无数据
收藏/分享
文件名: A High-Resolution MIR Echelle Grating Spectrom.pdf
格式: Adobe PDF
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。