CIOMP OpenIR
Effect of Wavelength Drift on PLSR Calibration Model of Near-Infrared Spectroscopy
Q.-P. Lu; D.-M. Wang; Y. Song; H.-Q. Ding and H.-Z. Gao
2022
发表期刊Guang Pu Xue Yu Guang Pu Fen Xi/Spectroscopy and Spectral Analysis
ISSN10000593
卷号42期号:2页码:405-409
摘要Partial least squares regression (PLSR) calibration model will be effect by the wavelength change of a single instrument at a different time and the wavelength consistency of multiple instruments. The process of near-infrared spectroscopy analysis, this problems can be unified as the effect of wavelength drift on chemometric calibration model. In this paper, taking the analysis of crude protein in wheat flour as an example, two calibration models I and II were established by partial least squares regression (PLSR) method within different spectral regions. Different types and amplitudes of wavelength shift information were generated by computer and superimposed into the spectra of the validation set to produce wavelength shift information relative to the spectra of calibration set, the effect of wavelength drift on PLSR calibration model was studied by adding different types and amplitude of wavelength drift information to the spectra of the validation set samples. The results show that the RMSEP of every model is no more than 0.3% and the corresponding Rp is no less than 0.98 when there is no wavelength drift information in the spectra of validation set samples. When the wavelength drift at different wavelengths is constant, the RMSEP increases as the wavelength drift amplitude increases, the RMSEP increases to 3.69% when the wavelength drift is -32 cm-1, and the Rp is almost constant; When the wavelength drift varies randomly at different wavelengths, the prediction results of model II based on long wavelength regions are almost not affected. The model II is corrected by a series of spectra added to the calibration set with different wavelength drift information, the RMSEP of the corrected model is 0.3%, The influence of wavelength drift information on RMSEP has been almost eliminated, but the number of regression factors used to establish corredted model increases significantly from 3 to 8, the robustness of the model varies greatly. In general, the RMSEP can be polished by correcting the prediction results to ensure the accuracy of the analysis results if the amplitude of wavelength drift is slight. This study provides an experimental basis for determining the design instrument parameters and operating procedures to improve the reliability of NIR analysis results. 2022, Peking University Press. All right reserved.
DOI10.3964/j.issn.1000-0593(2022)02-0405-05
URL查看原文
收录类别sci ; ei
引用统计
文献类型期刊论文
条目标识符http://ir.ciomp.ac.cn/handle/181722/66593
专题中国科学院长春光学精密机械与物理研究所
推荐引用方式
GB/T 7714
Q.-P. Lu,D.-M. Wang,Y. Song,et al. Effect of Wavelength Drift on PLSR Calibration Model of Near-Infrared Spectroscopy[J]. Guang Pu Xue Yu Guang Pu Fen Xi/Spectroscopy and Spectral Analysis,2022,42(2):405-409.
APA Q.-P. Lu,D.-M. Wang,Y. Song,&H.-Q. Ding and H.-Z. Gao.(2022).Effect of Wavelength Drift on PLSR Calibration Model of Near-Infrared Spectroscopy.Guang Pu Xue Yu Guang Pu Fen Xi/Spectroscopy and Spectral Analysis,42(2),405-409.
MLA Q.-P. Lu,et al."Effect of Wavelength Drift on PLSR Calibration Model of Near-Infrared Spectroscopy".Guang Pu Xue Yu Guang Pu Fen Xi/Spectroscopy and Spectral Analysis 42.2(2022):405-409.
条目包含的文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
Effect of Wavelength(1528KB)期刊论文出版稿开放获取CC BY-NC-SA浏览 请求全文
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Q.-P. Lu]的文章
[D.-M. Wang]的文章
[Y. Song]的文章
百度学术
百度学术中相似的文章
[Q.-P. Lu]的文章
[D.-M. Wang]的文章
[Y. Song]的文章
必应学术
必应学术中相似的文章
[Q.-P. Lu]的文章
[D.-M. Wang]的文章
[Y. Song]的文章
相关权益政策
暂无数据
收藏/分享
文件名: Effect of Wavelength Drift on PLSR Calibration Model of Near-Infrared Spectroscopy.pdf
格式: Adobe PDF
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。