摘要The imaging quality of the synthetic aperture system is sensitive to the positioning accuracy of the sub-aperture primary mirror. A novel flexible mounting structure of bimetallic material is proposed for the athermalization of the sub-aperture primary mirror of the Fizeau Synthetic Aperture Telescope - which is composed of seven sub-aperture. The axial position accuracy of the sub-aperture primary mirror must be less than 5 mu m under 10 degrees C temperature rise to meet the requirements of the optical system. Firstly, a single mounting unit is analyzed theoretically, and the initial parameters are determined. The conceptual design of the mounting structure is carried out by using initial parameters. The orthogonal optimization algorithm and range analysis are used to optimize the structural parameters. The finite element model of the flexible mounting structure is established and the coupled thermal-mechanical simulation analysis is performed. Then the thermal sensitivity test of the sub-aperture primary mirror mounting structure was carried out. Under the effect of a temperature rise of 10 degrees C, the axial displacement of the sub-aperture primary mirror mounting surface is less than 3 mu m. Finally, the synthetic aperture system is assembled, and the optical test verifies that the synthetic aperture system has good imaging capabilities.
DOI10.1177/16878140211067044
URL查看原文
收录类别sci
语种英语
引用统计
文献类型期刊论文
条目标识符http://ir.ciomp.ac.cn/handle/181722/66537
专题中国科学院长春光学精密机械与物理研究所
推荐引用方式
GB/T 7714
Y. F. Li,Z. X. Li,Q. Yong,et al. Design of athermalized mounting structure for the sub-aperture primary mirror of a synthetic aperture telescope[J]. Advances in Mechanical Engineering,2022,14(1):11.
APA Y. F. Li,Z. X. Li,Q. Yong,&T. C. Wang and D. F. Zhang.(2022).Design of athermalized mounting structure for the sub-aperture primary mirror of a synthetic aperture telescope.Advances in Mechanical Engineering,14(1),11.
MLA Y. F. Li,et al."Design of athermalized mounting structure for the sub-aperture primary mirror of a synthetic aperture telescope".Advances in Mechanical Engineering 14.1(2022):11.
条目包含的文件 下载所有文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
Design of athermaliz(2596KB)期刊论文出版稿开放获取CC BY-NC-SA浏览 下载
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Y. F. Li]的文章
[Z. X. Li]的文章
[Q. Yong]的文章
百度学术
百度学术中相似的文章
[Y. F. Li]的文章
[Z. X. Li]的文章
[Q. Yong]的文章
必应学术
必应学术中相似的文章
[Y. F. Li]的文章
[Z. X. Li]的文章
[Q. Yong]的文章
相关权益政策
暂无数据
收藏/分享
文件名: Design of athermalized mounting structure for the sub-aperture primary mirror of a synthetic aperture telescope.pdf
格式: Adobe PDF
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。