CIOMP OpenIR
Study on Signal Enhancement Technology for Atomic Fluorescence Spectrometry Based on Digital Micromirror Device
H. X. Wang; Y. C. Li; C. S. Li; Z. H. Zhou; Z. Y. Ma and D. Tian
2021
发表期刊Chinese Journal of Analytical Chemistry
ISSN0253-3820
卷号49期号:9
摘要A dispersive detection system based on ultraviolet digital micromirror device (DMD) was used for hydride generation atomic fluorescence spectrometer (HG-AFS) on the basis of the original non-dispersion detection system. The dispersion system was used to suppress the interference when spectral interference from the light source or scattering interference exists. The limit of detection (LOD) of the dispersive system was worse than the non-dispersive one due to the addition of the dispersive components (DMD and grating , etc) . In this work , to improve the analytical performance of the dispersive detection method , a cylindrical mirror was installed in front of the photomultiplier tube (PMT) , the minimum effective area of the PMT was expanded to enhance the signal intensity, a better fixed location mode of DMD rotation was proposed, and the analysis methods such as peak selection and the instrument parameters affecting the signal intensity were optimized. The results showed that the signal intensity within 180-320 nm was increased more than 2 times , and the spectral resolution was increased more than 1.2 times. Moreover, the emission lines and excitation fluorescence lines of Cd, Te, Sn and Zn were obtained, and the LODs were respectively less than 0. 005 ng/mL for Cd, 0. 02 ng/mL for Sn, 0. 1 ng/mL for As, Bi and Hg, 0. 05 ng/mL for Sb , Pb and Te, and 0. 2 ng/mL for Se and Zn. The spiked recoveries and the RSDs of As were 93% - 101% and 0. 6% - 3. 3% in living and drinking water samples , and 95% - 106% and 0. 9% - 3. 4% in food samples , respectively. The LOD and resolution of the dispersive system were effectively improved because of the improvement of the ultraviolet DMD spectrometer, the upgrade of the DMD rotation detection mode and the optimization of the analysis method. As a result, the dispersive system met the detection requirements of toxicological index limits in the Standards 14 Drinking Water Quality (GB 5749-2006) , and also had good accuracy, sensitivity and stability in actual food sample analysis.
DOI10.19756/j.issn.0253-3820.210467
URL查看原文
收录类别SCI
引用统计
文献类型期刊论文
条目标识符http://ir.ciomp.ac.cn/handle/181722/65664
专题中国科学院长春光学精密机械与物理研究所
推荐引用方式
GB/T 7714
H. X. Wang,Y. C. Li,C. S. Li,et al. Study on Signal Enhancement Technology for Atomic Fluorescence Spectrometry Based on Digital Micromirror Device[J]. Chinese Journal of Analytical Chemistry,2021,49(9).
APA H. X. Wang,Y. C. Li,C. S. Li,Z. H. Zhou,&Z. Y. Ma and D. Tian.(2021).Study on Signal Enhancement Technology for Atomic Fluorescence Spectrometry Based on Digital Micromirror Device.Chinese Journal of Analytical Chemistry,49(9).
MLA H. X. Wang,et al."Study on Signal Enhancement Technology for Atomic Fluorescence Spectrometry Based on Digital Micromirror Device".Chinese Journal of Analytical Chemistry 49.9(2021).
条目包含的文件 下载所有文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
Study on Signal Enha(4282KB)期刊论文出版稿开放获取CC BY-NC-SA浏览 下载
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[H. X. Wang]的文章
[Y. C. Li]的文章
[C. S. Li]的文章
百度学术
百度学术中相似的文章
[H. X. Wang]的文章
[Y. C. Li]的文章
[C. S. Li]的文章
必应学术
必应学术中相似的文章
[H. X. Wang]的文章
[Y. C. Li]的文章
[C. S. Li]的文章
相关权益政策
暂无数据
收藏/分享
文件名: Study on Signal Enhancement Technology for Ato.pdf
格式: Adobe PDF
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。