CIOMP OpenIR
Quantum efficiency test system based on focusing scanning for linear array camera
Y.-F. Tang; J.-L. Li; Y.-Q. Yang; Z.-M. Li and H. B
2021
发表期刊Guangxue Jingmi Gongcheng/Optics and Precision Engineering
ISSN1004924X
卷号29期号:5页码:975-981
摘要In order to measure the quantum efficiency of linear array image sensor (hereinafter referred to as linear array camera), a set of quantum efficiency measurement system based on focusing scanning method is established. A linear array CMOS camera is tested and the uncertainty of the test results is analyzed. Firstly, a test system composed of a lighting source, a monochromator, a scanning motion mechanism and a standard detector is built. Then the scanning motion mechanism is used to drive the linear array camera and the standard detector to move with high precision and uniform speed so that the camera can scan and image the generated monochromatic spot. By switching the position between the linear array camera and the standard detector, the energy of the monochromatic spot can be measured. Finally, the sum of gray scale of the images collected by the linear array camera and the sum of the light energy detected by the standard detector are analyzed and calculated. Combined with the theoretical formula of the focused scanning method, the quantum efficiency of the linear array camera is obtained. The test results show that the focusing scanning method is feasible for measuring the quantum efficiency of linear array camera, and the repeatability accuracy is high. By analyzing the uncertainty of the test results, the measurement accuracy of the quantum efficiency of this method is about 2.6%. Quantum efficiency measurement system for focused scanning linear array camera innovatively proposes the dynamic linear scanning focusing measurement of linear array camera quantum efficiency. This system is different from the traditional quantum efficiency test method for planar array camera that irradiated by monochromatic light combined with integrating sphere in principle, and makes up for the shortage of the linear array camera's quantum efficiency testing methods and low precision. In addition, the application of focusing scanning method to measure quantum efficiency is not limited to linear array cameras, but can also test photoelectric parameters of various types of cameras, and the measurement accuracy can meet the requirements of most projects.
DOI10.37188/OPE.20212905.0975
URL查看原文
收录类别EI
引用统计
文献类型期刊论文
条目标识符http://ir.ciomp.ac.cn/handle/181722/65564
专题中国科学院长春光学精密机械与物理研究所
推荐引用方式
GB/T 7714
Y.-F. Tang,J.-L. Li,Y.-Q. Yang,et al. Quantum efficiency test system based on focusing scanning for linear array camera[J]. Guangxue Jingmi Gongcheng/Optics and Precision Engineering,2021,29(5):975-981.
APA Y.-F. Tang,J.-L. Li,Y.-Q. Yang,&Z.-M. Li and H. B.(2021).Quantum efficiency test system based on focusing scanning for linear array camera.Guangxue Jingmi Gongcheng/Optics and Precision Engineering,29(5),975-981.
MLA Y.-F. Tang,et al."Quantum efficiency test system based on focusing scanning for linear array camera".Guangxue Jingmi Gongcheng/Optics and Precision Engineering 29.5(2021):975-981.
条目包含的文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
Quantum efficiency t(1411KB)期刊论文出版稿开放获取CC BY-NC-SA浏览 请求全文
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Y.-F. Tang]的文章
[J.-L. Li]的文章
[Y.-Q. Yang]的文章
百度学术
百度学术中相似的文章
[Y.-F. Tang]的文章
[J.-L. Li]的文章
[Y.-Q. Yang]的文章
必应学术
必应学术中相似的文章
[Y.-F. Tang]的文章
[J.-L. Li]的文章
[Y.-Q. Yang]的文章
相关权益政策
暂无数据
收藏/分享
文件名: Quantum efficiency test system based on focusi.pdf
格式: Adobe PDF
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。