Parameter calibration of 6-dof parallel mechanism using orthogonal displacement measurement system
L.-W. Yang; H. Bao; Y.-C. Fan; Z.-L. Li and D.-Y. Dong
2021
发表期刊Guangxue Jingmi Gongcheng/Optics and Precision Engineering
ISSN1004924X
卷号29期号:2页码:316-328
摘要In order to simplify the parameter calibration process of 6-DOF parallel mechanism, improve the calibration efficiency and reduce the calibration, a novel device and method of pose measurement based on orthogonal displacement measurement system is described.First, the pose calculation method of the device is studied, and the forward and reverse kinematic solution is solved by using the method of spatial analytic geometry. Secondary, the error model of the combination of parallel mechanism and orthogonal displacement measurement system is established by using the method of micro displacement synthesis. Then, based on the error model, the model of optimal problem of parameter identification is constructed. The minimum square sum of the sensor indication error is the objective function, and the parameter error of the combination is the variables. Finally, the pose of the parallel mechanism are measured by orthogonal displacement measurement system, and the optimal solution of the parameter error is found by OASIS, and model parameter in the control system is compensated.the calibration of parallel mechanism is completed.The comparison of the pose error before and after calibration show that: the maximum position error is reduced by 58%-96%, the maximum attitude error is reduced by 92%-97%.Using the orthogonal displacement measurement system to calibration the parameters of the parallel mechanism can not only improve the position accuracy of the parallel mechanism, but also simplify the calibration work, improve the calibration efficiency and reduce the cost. 2021, Science Press. All right reserved.
DOI10.37188/OPE.20212902.0316
URL查看原文
收录类别EI
引用统计
文献类型期刊论文
条目标识符http://ir.ciomp.ac.cn/handle/181722/65515
专题中国科学院长春光学精密机械与物理研究所
推荐引用方式
GB/T 7714
L.-W. Yang,H. Bao,Y.-C. Fan,et al. Parameter calibration of 6-dof parallel mechanism using orthogonal displacement measurement system[J]. Guangxue Jingmi Gongcheng/Optics and Precision Engineering,2021,29(2):316-328.
APA L.-W. Yang,H. Bao,Y.-C. Fan,&Z.-L. Li and D.-Y. Dong.(2021).Parameter calibration of 6-dof parallel mechanism using orthogonal displacement measurement system.Guangxue Jingmi Gongcheng/Optics and Precision Engineering,29(2),316-328.
MLA L.-W. Yang,et al."Parameter calibration of 6-dof parallel mechanism using orthogonal displacement measurement system".Guangxue Jingmi Gongcheng/Optics and Precision Engineering 29.2(2021):316-328.
条目包含的文件 下载所有文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
Parameter calibratio(2206KB)期刊论文出版稿开放获取CC BY-NC-SA浏览 下载
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[L.-W. Yang]的文章
[H. Bao]的文章
[Y.-C. Fan]的文章
百度学术
百度学术中相似的文章
[L.-W. Yang]的文章
[H. Bao]的文章
[Y.-C. Fan]的文章
必应学术
必应学术中相似的文章
[L.-W. Yang]的文章
[H. Bao]的文章
[Y.-C. Fan]的文章
相关权益政策
暂无数据
收藏/分享
文件名: Parameter calibration of 6-dof parallel mechan.pdf
格式: Adobe PDF
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。