CIOMP OpenIR
Influence of alignment error on DMD super-resolution imaging optical system
S.-Y. Xing; C. Wang; M. Xu; Y.-C. Li; H.-D. Shi; Z. Liu and Q. Fu
2021
发表期刊Chinese Optics
ISSN20951531
卷号14期号:5页码:1194-1201
摘要At present, most of the research on super-resolution imaging technology is focused on the super-resolution reconstruction algorithm, but the influence of the alignment error of an optical system on the super-resolution imaging results has not been reported. To solve this problem, We researche the influence of alignment error on super-resolution imaging. First, the basic imaging model of super-resolution imaging optical system based on Digital Micro-mirror Device (DMD) is established. A DMD super-resolution imaging optical system with operating band of 8~12 m is designed, and a method used to analyze the influence of the alignment error on super-resolution imaging quality is proposed. In the imaging model, alignment errors such as eccentricity, tilt, lens spacing error and defocus are introduced, and the reconstruction results are analyzed. Finally, the range of tolerance of the super-resolution imaging optical system is obtained. The results show that the total eccentricity error in the X direction is controlled within 0.07 mm, and that in the Y direction is within 0.05 mm; the total tilt error in the X and Y directions is controlled within 0.06; the overall lens spacing error is controlled within 0.02 mm; the defocusing amount of the imaging object lens is controlled within 0.04 mm; the defocusing amount of the projection objective lens is controlled within 0.05 mm, and within this range, the super-resolution imaging optical system can ensure the quality of super-resolution imaging. 2021, China Science Publishing & Media LTD. All right reserved.
DOI10.37188/CO.2020-0220
URL查看原文
收录类别EI
引用统计
文献类型期刊论文
条目标识符http://ir.ciomp.ac.cn/handle/181722/65337
专题中国科学院长春光学精密机械与物理研究所
推荐引用方式
GB/T 7714
S.-Y. Xing,C. Wang,M. Xu,et al. Influence of alignment error on DMD super-resolution imaging optical system[J]. Chinese Optics,2021,14(5):1194-1201.
APA S.-Y. Xing,C. Wang,M. Xu,Y.-C. Li,H.-D. Shi,&Z. Liu and Q. Fu.(2021).Influence of alignment error on DMD super-resolution imaging optical system.Chinese Optics,14(5),1194-1201.
MLA S.-Y. Xing,et al."Influence of alignment error on DMD super-resolution imaging optical system".Chinese Optics 14.5(2021):1194-1201.
条目包含的文件 下载所有文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
Influence of alignme(8768KB)期刊论文出版稿开放获取CC BY-NC-SA浏览 下载
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[S.-Y. Xing]的文章
[C. Wang]的文章
[M. Xu]的文章
百度学术
百度学术中相似的文章
[S.-Y. Xing]的文章
[C. Wang]的文章
[M. Xu]的文章
必应学术
必应学术中相似的文章
[S.-Y. Xing]的文章
[C. Wang]的文章
[M. Xu]的文章
相关权益政策
暂无数据
收藏/分享
文件名: Influence of alignment error on DMD super-reso.pdf
格式: Adobe PDF
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。