Changchun Institute of Optics,Fine Mechanics and Physics,CAS
Analysis of temperature-induced spectral drift in the solar spectrometer driven by leadscrew and bar mechanism | |
Q. Cui; Z. Li; Z. Zhang; X. Yang; S. Wang; D. Cao and Y. Huang | |
2021 | |
发表期刊 | Optik
![]() |
ISSN | 304026 |
卷号 | 225 |
摘要 | A solar spectrometer is designed and developed, which uses a leadscrew and bar mechanism as the wavelength scanning mechanism, to achieve the accurate measurement of the solar spectrum in 170 nm350 nm range. When measuring the standard spectrum of mercury lamp under laboratory conditions, there is a spectral drift due to temperature-induced deformation of the wavelength scanning mechanism. By using the finite element analysis method, the temperature sensitivity of each component in mechanism is analyzed. And then the linear superposition relationship between temperature rise and deformation is determined. Combined with the working principle of wavelength scanning mechanism, the corresponding relationship between temperature change and spectral drift is deduced. Spectral scanning and temperature monitoring were carried out simultaneously in instrument test to acquire temperature data of the wavelength scanning mechanism as it driving the gratings. Spectral drift was estimated according to the temperature variation and the maximum deviation between the predicted wavelength drift and the measured wavelength drift is 0.0016 nm, which is 6% of the measured wavelength. The experiment data validate the theoretical analysis results. The relationship between temperature change and spectral drift provides a theoretical reference for the correction of the measurement results and the thermal control of the instrument. 2020 |
DOI | 10.1016/j.ijleo.2020.165783 |
URL | 查看原文 |
收录类别 | SCI ; EI |
引用统计 | |
文献类型 | 期刊论文 |
条目标识符 | http://ir.ciomp.ac.cn/handle/181722/65049 |
专题 | 中国科学院长春光学精密机械与物理研究所 |
推荐引用方式 GB/T 7714 | Q. Cui,Z. Li,Z. Zhang,et al. Analysis of temperature-induced spectral drift in the solar spectrometer driven by leadscrew and bar mechanism[J]. Optik,2021,225. |
APA | Q. Cui,Z. Li,Z. Zhang,X. Yang,S. Wang,&D. Cao and Y. Huang.(2021).Analysis of temperature-induced spectral drift in the solar spectrometer driven by leadscrew and bar mechanism.Optik,225. |
MLA | Q. Cui,et al."Analysis of temperature-induced spectral drift in the solar spectrometer driven by leadscrew and bar mechanism".Optik 225(2021). |
条目包含的文件 | 下载所有文件 | |||||
文件名称/大小 | 文献类型 | 版本类型 | 开放类型 | 使用许可 | ||
Analysis of temperat(3377KB) | 期刊论文 | 出版稿 | 开放获取 | CC BY-NC-SA | 浏览 下载 |
个性服务 |
推荐该条目 |
保存到收藏夹 |
查看访问统计 |
导出为Endnote文件 |
谷歌学术 |
谷歌学术中相似的文章 |
[Q. Cui]的文章 |
[Z. Li]的文章 |
[Z. Zhang]的文章 |
百度学术 |
百度学术中相似的文章 |
[Q. Cui]的文章 |
[Z. Li]的文章 |
[Z. Zhang]的文章 |
必应学术 |
必应学术中相似的文章 |
[Q. Cui]的文章 |
[Z. Li]的文章 |
[Z. Zhang]的文章 |
相关权益政策 |
暂无数据 |
收藏/分享 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论