CIOMP OpenIR
Active vibration control method of double crystal monochromator of P2 protein crystallography beam line at SSRF
Y. Bai; G. X; L. Q; S. Y; W. D; P. Z; Z. Z; M. Q and M. T
2021
发表期刊Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
ISSN1689002
卷号1019
摘要The angular stability of the double-crystal monochromator (DCM) directly affects the positional stability of the focused spot. This paper describes the active vibration control (AVC) method of the DCM of P2 Experimental Station at SSRF based on the adaptive filtering algorithm and the AVC system improves the performance of by optimizing the filter weight estimation algorithm. The simulation results show that the amplitude of the crystal in the pitch direction is greatly reduced by the AVC method, the RMS value of the angular displacement in the pitch direction of the crystal is 1.23 nrad, which is 91.93% lower than the passive vibration control (the RMS value of the angular displacement in the pitch direction is 15.25 nrad); the RMS value of the angular displacement in the pitch direction of the optimized AVC system is 0.233 nrad, which is 98.47% lower than that of the passive vibration control method. The AVC method can effectively ensure the angular stability of the DCM in the pitch direction, which is of great significance for the key equipment of the new generation of synchrotron radiation light source to achieve nano-radian stability. 2021
DOI10.1016/j.nima.2021.165906
URL查看原文
收录类别SCI ; EI
引用统计
文献类型期刊论文
条目标识符http://ir.ciomp.ac.cn/handle/181722/65026
专题中国科学院长春光学精密机械与物理研究所
推荐引用方式
GB/T 7714
Y. Bai,G. X,L. Q,et al. Active vibration control method of double crystal monochromator of P2 protein crystallography beam line at SSRF[J]. Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment,2021,1019.
APA Y. Bai.,G. X.,L. Q.,S. Y.,W. D.,...&M. Q and M. T.(2021).Active vibration control method of double crystal monochromator of P2 protein crystallography beam line at SSRF.Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment,1019.
MLA Y. Bai,et al."Active vibration control method of double crystal monochromator of P2 protein crystallography beam line at SSRF".Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 1019(2021).
条目包含的文件 下载所有文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
Active vibration con(3010KB)期刊论文出版稿开放获取CC BY-NC-SA浏览 下载
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Y. Bai]的文章
[G. X]的文章
[L. Q]的文章
百度学术
百度学术中相似的文章
[Y. Bai]的文章
[G. X]的文章
[L. Q]的文章
必应学术
必应学术中相似的文章
[Y. Bai]的文章
[G. X]的文章
[L. Q]的文章
相关权益政策
暂无数据
收藏/分享
文件名: Active vibration control method of double crys.pdf
格式: Adobe PDF
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。