CIOMP OpenIR
Trace Methane Detection Based on Cavity Ring-Down Spectroscopy
S. M. Song and C. X. Yan
2020
发表期刊Spectroscopy and Spectral Analysis
ISSN1000-0593
卷号40期号:7页码:2023-2028
摘要In order to accurately measure the trace methane (CH4) concentration in nitrogen, a continuous wave-Cavity Ring-Down Spectrometer (CW-CRDS) measuring device based on the triangular annular cavity was designed and built. The ring-down cavity is designed for autonomous processing. It consists of a concave mirror with a radius of curvature of 1 m and a diameter of 25 mm and two plane mirrors with a diameter of 12. 7 mm. The total length of the optical path in the cavity is 410 mm, and the cavity material is Invar. First, we measured the baseline loss of the system, and then used nitrogen as the mixture to configure a mixture of five different concentrations of CH4 and N-2. The gas was detected by the absorption peak of CH4 at 1 653. 7 nm (CH(4)v3 with R5). According to the absorption line characteristics, the attenuation time constant tau is calculated by the least square method using the Lorentz linear function and the CH4 concentration is calculated. The detection sensitivity of the built device to the methane volume concentration can reach 54 x 10(-9) (540 million). Finally, the absorption spectrum of CH4 with a volume concentration of 5(10) x 10(-9) in the range of 6 046. 7 similar to 6 047.2 cm(-1) was measured, and the measured data was determined according to the cavity free spectrum. The range (Free Spectral Range, FSR) is fitted to the 7 and the absorption coefficient respectively. The obtained CH4 absorption coefficient is compared with the data in the database. The maximum error is less than 1. 2 x 10(-9) cm(-1) and the highest precision is 8. 8 x 10(-11) cm(-1).
DOI10.3964/j.issn.1000-0593(2020)07-2023-06
URL查看原文
收录类别SCI ; EI
语种中文
引用统计
文献类型期刊论文
条目标识符http://ir.ciomp.ac.cn/handle/181722/64974
专题中国科学院长春光学精密机械与物理研究所
推荐引用方式
GB/T 7714
S. M. Song and C. X. Yan. Trace Methane Detection Based on Cavity Ring-Down Spectroscopy[J]. Spectroscopy and Spectral Analysis,2020,40(7):2023-2028.
APA S. M. Song and C. X. Yan.(2020).Trace Methane Detection Based on Cavity Ring-Down Spectroscopy.Spectroscopy and Spectral Analysis,40(7),2023-2028.
MLA S. M. Song and C. X. Yan."Trace Methane Detection Based on Cavity Ring-Down Spectroscopy".Spectroscopy and Spectral Analysis 40.7(2020):2023-2028.
条目包含的文件 下载所有文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
Trace Methane Detect(1367KB)期刊论文出版稿开放获取CC BY-NC-SA浏览 下载
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[S. M. Song and C. X. Yan]的文章
百度学术
百度学术中相似的文章
[S. M. Song and C. X. Yan]的文章
必应学术
必应学术中相似的文章
[S. M. Song and C. X. Yan]的文章
相关权益政策
暂无数据
收藏/分享
文件名: Trace Methane Detection Based on Cavity Ring-Down Spectroscopy.pdf
格式: Adobe PDF
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。