CIOMP OpenIR
Sub-ppm CO detection in a sub-meter-long hollow-core negative curvature fiber using absorption spectroscopy at 2.3 mu m
C. Y. Yao,L. M. Xiao,S. F. Gao,Y. Y. Wang,P. Wang,R. F. Kan,W. Jin and W. Ren
2020
发表期刊Sensors and Actuators B-Chemical
卷号303页码:6
摘要We demonstrated the sensitive CO detection in a novel hollow-core negative curvature fiber (HC-NCF) with infrared laser absorption at 2.3 mu m. The HC-NCF consists of a single ring of eight nontouching silica capillaries around the air core, providing a single-mode light delivery of the 2.3-mu m distributed feedback laser. A high coupling efficiency of 90% was achieved with the aid of optimal free-space coupling optics. The hollow-core fiber was used as a gas cell for gas absorption measurement of a total path length of 85 cm. Both direct absorption spectroscopy (DAS) and wavelength modulation spectroscopy (WMS) were adopted to demonstrate the sensor performance by detecting the CO line R(10) at 4297.7 cm(-1). In scanned-wavelength DAS, we obtained a minimum detection limit (MDL) of 13 ppm CO, which was limited mainly by the existing mode noise in the HC-NCF. By applying a pressure difference of 0.8 bar between the two ends of the fiber, we demonstrated a very short gas loading time of only 5 s. Finally, we achieved a MDL of 0.4 ppm CO using the WMS technique, corresponding to a noise equivalent absorption of 1.6 x 10(-7) cm(-1).
DOI10.1016/j.snb.2019.127238
URL查看原文
收录类别SCI
语种英语
引用统计
文献类型期刊论文
条目标识符http://ir.ciomp.ac.cn/handle/181722/64926
专题中国科学院长春光学精密机械与物理研究所
推荐引用方式
GB/T 7714
C. Y. Yao,L. M. Xiao,S. F. Gao,Y. Y. Wang,P. Wang,R. F. Kan,W. Jin and W. Ren. Sub-ppm CO detection in a sub-meter-long hollow-core negative curvature fiber using absorption spectroscopy at 2.3 mu m[J]. Sensors and Actuators B-Chemical,2020,303:6.
APA C. Y. Yao,L. M. Xiao,S. F. Gao,Y. Y. Wang,P. Wang,R. F. Kan,W. Jin and W. Ren.(2020).Sub-ppm CO detection in a sub-meter-long hollow-core negative curvature fiber using absorption spectroscopy at 2.3 mu m.Sensors and Actuators B-Chemical,303,6.
MLA C. Y. Yao,L. M. Xiao,S. F. Gao,Y. Y. Wang,P. Wang,R. F. Kan,W. Jin and W. Ren."Sub-ppm CO detection in a sub-meter-long hollow-core negative curvature fiber using absorption spectroscopy at 2.3 mu m".Sensors and Actuators B-Chemical 303(2020):6.
条目包含的文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
Sub-ppm CO detection(1588KB)期刊论文出版稿开放获取CC BY-NC-SA浏览 请求全文
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[C. Y. Yao,L. M. Xiao,S. F. Gao,Y. Y. Wang,P. Wang,R. F. Kan,W. Jin and W. Ren]的文章
百度学术
百度学术中相似的文章
[C. Y. Yao,L. M. Xiao,S. F. Gao,Y. Y. Wang,P. Wang,R. F. Kan,W. Jin and W. Ren]的文章
必应学术
必应学术中相似的文章
[C. Y. Yao,L. M. Xiao,S. F. Gao,Y. Y. Wang,P. Wang,R. F. Kan,W. Jin and W. Ren]的文章
相关权益政策
暂无数据
收藏/分享
文件名: Sub-ppm CO detection in a sub-meter-long hollo.pdf
格式: Adobe PDF
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。