摘要A high accuracy instrument calibration is the guarantee of obtaining high precision atmospheric inversion data from a wavelength-dispersive space remote sensing instrument in the orbit. To improve the relative calibration uncertainty of a dual-grating spectrometer in the vacuum-ultraviolet (VUV) band, conventional secondary standard light sources, such as deuterium lamps, used in laboratory calibrating stations are not suited to meet high precision. In this paper we present the calibration of the space instrument based on the Metrology Light Source (MLS) of the Physikalisch-Technische Bundesanstalt (PTB) operated as a primary synchrotron radiation (SR) source with calculable spectral radiant intensity to overcome the limit imposed by secondary transfer standards. For taking into account the difference between the highly linearly polarized SR source and the un-polarized solar radiation, which will be observed by the dual-grating spectrometer in orbit, the calibration was performed at two orientations of the instrument, which are perpendicular to each other with respect to the incident SR. The factors contributing to the uncertainty budget were analyzed. It could be shown that a total relative uncertainty of 2.52% can be achieved, which has greatly improved the calibrating accuracy compared with that obtainable with the conventional standard light source calibrating stations in the VUV spectral range.
DOI10.1016/j.optcom.2020.126254
URL查看原文
收录类别SCI ; EI
语种英语
引用统计
文献类型期刊论文
条目标识符http://ir.ciomp.ac.cn/handle/181722/64851
专题中国科学院长春光学精密机械与物理研究所
推荐引用方式
GB/T 7714
H. S. Li,B. Li,S. R. Wang,Z. F. Li,J. Qi,M. Yu,Y. Huang,Y. Li,A. Barbutis,J. Lubeck,R. Klein,S. Kroth,W. Paustian,M. Ressin and R. Thornagel. Research on the irradiance calibration of a VUV dual-grating spectrometer based on synchrotron radiation[J]. Optics Communications,2020,475:5.
APA H. S. Li,B. Li,S. R. Wang,Z. F. Li,J. Qi,M. Yu,Y. Huang,Y. Li,A. Barbutis,J. Lubeck,R. Klein,S. Kroth,W. Paustian,M. Ressin and R. Thornagel.(2020).Research on the irradiance calibration of a VUV dual-grating spectrometer based on synchrotron radiation.Optics Communications,475,5.
MLA H. S. Li,B. Li,S. R. Wang,Z. F. Li,J. Qi,M. Yu,Y. Huang,Y. Li,A. Barbutis,J. Lubeck,R. Klein,S. Kroth,W. Paustian,M. Ressin and R. Thornagel."Research on the irradiance calibration of a VUV dual-grating spectrometer based on synchrotron radiation".Optics Communications 475(2020):5.
条目包含的文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
Research on the irra(986KB)期刊论文出版稿开放获取CC BY-NC-SA浏览 请求全文
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[H. S. Li,B. Li,S. R. Wang,Z. F. Li,J. Qi,M. Yu,Y. Huang,Y. Li,A. Barbutis,J. Lubeck,R. Klein,S. Kroth,W. Paustian,M. Ressin and R. Thornagel]的文章
百度学术
百度学术中相似的文章
[H. S. Li,B. Li,S. R. Wang,Z. F. Li,J. Qi,M. Yu,Y. Huang,Y. Li,A. Barbutis,J. Lubeck,R. Klein,S. Kroth,W. Paustian,M. Ressin and R. Thornagel]的文章
必应学术
必应学术中相似的文章
[H. S. Li,B. Li,S. R. Wang,Z. F. Li,J. Qi,M. Yu,Y. Huang,Y. Li,A. Barbutis,J. Lubeck,R. Klein,S. Kroth,W. Paustian,M. Ressin and R. Thornagel]的文章
相关权益政策
暂无数据
收藏/分享
文件名: Research on the irradiance calibration of a VUV dual-grating spectrometer based on synchrotron radiation.pdf
格式: Adobe PDF
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。