CIOMP OpenIR
Radiometric Cross-Calibration of the Wide Field View Camera Onboard GaoFen-6 in Multispectral Bands
A. X. Yang,B. Zhong,L. F. Hu,S. L. Wu,Z. P. Xu,H. B. Wu,J. J. Wu,X. S. Gong,H. B. Wang and Q. H. Liu
2020
发表期刊Remote Sensing
卷号12期号:6页码:21
摘要GaoFen6 (GF-6), successfully launched on June 2, 2018, is the sixth satellite of the High-Definition Earth observation system (HDEOS). Although GF-6 is the first high-resolution satellite in China to achieve precise agricultural observation, it will be widely used in many other domains, such as land survey, natural resources management, emergency management, ecological environment and so on. The GF-6 was not equipped with an onboard calibration instrument, so on-orbit radiometric calibration is essential. This paper aimed at the on-orbit radiometric calibration of the wide field of view camera (WFV) onboard GF-6 (GF-6/WFV) in multispectral bands. Firstly, the radiometric capability of GF-6/WFV is evaluated compared with the Operational Land Imager (OLI) onboard Landsat-8, Multi Spectral Instrument (MSI) onboard Sentinel-2 and Moderate Resolution Imaging Spectroradiometer (MODIS) onboard Terra, which shows that GF-6/WFV has an obvious attenuation. Consequently, instead of vicarious calibration once a year, more frequent calibration is required to guarantee its radiometric consistency. The cross-calibration method based on the Badain Jaran Desert site using the bi-directional reflectance distribution function (BRDF) model calculated by Landsat-8/OLI and ZY-3/Three-Line Camera (TLC) data is subsequently applied to GF-6/WFV and much higher frequencies of calibration are achieved. Finally, the cross-calibration results are validated using the synchronized ground measurements at Dunhuang test site and the uncertainty of the proposed method is analyzed. The validation shows that the relative difference of cross-calibration is less than 5% and it is satisfied with the requirements of cross-calibration.
DOI10.3390/rs12061037
URL查看原文
收录类别SCI ; EI
语种英语
引用统计
文献类型期刊论文
条目标识符http://ir.ciomp.ac.cn/handle/181722/64822
专题中国科学院长春光学精密机械与物理研究所
推荐引用方式
GB/T 7714
A. X. Yang,B. Zhong,L. F. Hu,S. L. Wu,Z. P. Xu,H. B. Wu,J. J. Wu,X. S. Gong,H. B. Wang and Q. H. Liu. Radiometric Cross-Calibration of the Wide Field View Camera Onboard GaoFen-6 in Multispectral Bands[J]. Remote Sensing,2020,12(6):21.
APA A. X. Yang,B. Zhong,L. F. Hu,S. L. Wu,Z. P. Xu,H. B. Wu,J. J. Wu,X. S. Gong,H. B. Wang and Q. H. Liu.(2020).Radiometric Cross-Calibration of the Wide Field View Camera Onboard GaoFen-6 in Multispectral Bands.Remote Sensing,12(6),21.
MLA A. X. Yang,B. Zhong,L. F. Hu,S. L. Wu,Z. P. Xu,H. B. Wu,J. J. Wu,X. S. Gong,H. B. Wang and Q. H. Liu."Radiometric Cross-Calibration of the Wide Field View Camera Onboard GaoFen-6 in Multispectral Bands".Remote Sensing 12.6(2020):21.
条目包含的文件 下载所有文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
Yang-2020-Radiometri(4665KB)期刊论文出版稿开放获取CC BY-NC-SA浏览 下载
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[A. X. Yang,B. Zhong,L. F. Hu,S. L. Wu,Z. P. Xu,H. B. Wu,J. J. Wu,X. S. Gong,H. B. Wang and Q. H. Liu]的文章
百度学术
百度学术中相似的文章
[A. X. Yang,B. Zhong,L. F. Hu,S. L. Wu,Z. P. Xu,H. B. Wu,J. J. Wu,X. S. Gong,H. B. Wang and Q. H. Liu]的文章
必应学术
必应学术中相似的文章
[A. X. Yang,B. Zhong,L. F. Hu,S. L. Wu,Z. P. Xu,H. B. Wu,J. J. Wu,X. S. Gong,H. B. Wang and Q. H. Liu]的文章
相关权益政策
暂无数据
收藏/分享
文件名: Yang-2020-Radiometric Cross-Calibration of the.pdf
格式: Adobe PDF
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。