CIOMP OpenIR
Optimization of leakage detection system for vials based on two-line tunable diode laser absorption spectroscopy
Y. X. Zhang,W. W. Wu,H. N. Yang,C. L. Li,J. Tao and R. F. Kan
2020
发表期刊Spectrochimica Acta Part a-Molecular and Biomolecular Spectroscopy
ISSN1386-1425
卷号233页码:6
摘要The leakage detection system of vials based on two-line water-vapor tunable diode laser absorption spectroscopy (TDLAS) developed in our previous work was first employed to investigate the instantaneous leakage processes of sealed vials. It showed that the leakage states of the vials with medicines cannot be accurately determined in a short time after the opening. Therefore, an optimized system was developed with two-line oxygen TDLAS method by the measurement of defined oxygen leakage coefficient, and it was then utilized to study the instantaneous leakage processes of sealed vials. It revealed that when the stoppers of the sealed vials were opened, the oxygen leakage coefficients increased immediately and then reach stable. It indicated that the optimized system was not affected by the water absorption of medicines. Furthermore, 15 vials with known leakage states were measured. It showed that the oxygen leakage coefficients of fully-open vials were obviously larger than that of sealed vials, and the maximum standard deviation of oxygen leakage coefficients for ten measurements of a single vial was 0.03%.The sealed vials with different leakage degrees were then investigated by inserting the needles with different sizes (05/1/2/3.5 min) into the vials. It revealed that the time required for the oxygen leakage coefficients to reach stable was shorter for the vials with larger leakage degree, i.e., larger needle size inserted. It showed that non-invasive, fast response and high-accuracy leakage detection of vials can be realized by the optimized system. (C) 2020 Elsevier B.V. All rights reserved.
DOI10.1016/j.saa.2020.118194
URL查看原文
收录类别SCI
语种英语
引用统计
文献类型期刊论文
条目标识符http://ir.ciomp.ac.cn/handle/181722/64767
专题中国科学院长春光学精密机械与物理研究所
推荐引用方式
GB/T 7714
Y. X. Zhang,W. W. Wu,H. N. Yang,C. L. Li,J. Tao and R. F. Kan. Optimization of leakage detection system for vials based on two-line tunable diode laser absorption spectroscopy[J]. Spectrochimica Acta Part a-Molecular and Biomolecular Spectroscopy,2020,233:6.
APA Y. X. Zhang,W. W. Wu,H. N. Yang,C. L. Li,J. Tao and R. F. Kan.(2020).Optimization of leakage detection system for vials based on two-line tunable diode laser absorption spectroscopy.Spectrochimica Acta Part a-Molecular and Biomolecular Spectroscopy,233,6.
MLA Y. X. Zhang,W. W. Wu,H. N. Yang,C. L. Li,J. Tao and R. F. Kan."Optimization of leakage detection system for vials based on two-line tunable diode laser absorption spectroscopy".Spectrochimica Acta Part a-Molecular and Biomolecular Spectroscopy 233(2020):6.
条目包含的文件 下载所有文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
Optimization of leak(1506KB)期刊论文出版稿开放获取CC BY-NC-SA浏览 下载
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Y. X. Zhang,W. W. Wu,H. N. Yang,C. L. Li,J. Tao and R. F. Kan]的文章
百度学术
百度学术中相似的文章
[Y. X. Zhang,W. W. Wu,H. N. Yang,C. L. Li,J. Tao and R. F. Kan]的文章
必应学术
必应学术中相似的文章
[Y. X. Zhang,W. W. Wu,H. N. Yang,C. L. Li,J. Tao and R. F. Kan]的文章
相关权益政策
暂无数据
收藏/分享
文件名: Optimization of leakage detection system for v.pdf
格式: Adobe PDF
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。