CIOMP OpenIR
Method for Measuring High Temperature Spectral Line Parameters Based on Calibration-Free Wavelength Modulation Technology
Y. Zang,Z. Xu,H. Xia,A. Huang,Y. He and R. Kan
2020
发表期刊Zhongguo Jiguang/Chinese Journal of Lasers
ISSN2587025
卷号47期号:10
摘要In the diagnosis of combustion flow field by absorption spectra, the accuracy of absorption molecular spectral line parameters directly affects the accuracy of the measurement of flow field parameters. In this paper, the absorption spectral line parameters of water molecules used as the main probe in combustion diagnostic studies are calibrated accurately. A near-infrared diode laser with a wavelength of 1469 nm is used as the light source, and the highly sensitive calibration-free wavelength modulation technology is used. Combining with the established laboratory high temperature measuring system, we obtain the modulation absorption spectra of the selected spectral lines in the temperature range of 9001500 K. By using the nonlinear least square L-M fitting method to fit the H2O absorption spectra, the line intensities, self-broadening coefficients, and temperature dependent coefficients of the selected spectral lines at 6807.83 cm-1 and 6808.04 cm-1 are accurately obtained. By comparing the HITRAN and HITEMP databases, we obtain that the relative deviations of line strengths are 3.91% and -5.40%, the relative deviations of self-broadening coefficients are 3.01% and -6.49%, the temperature dependence coefficients are 0.5213 and 0.4567, and the uncertainties of the experimental results of the two line strengths are 1.05% and 1.96%, respectively. The spectral parameter calibration method based on calibration-free wavelength modulation has the advantages of high detection sensitivity and spectral signal-to-noise ratio in high temperature spectral measurement, which is conductive to improve the accuracy of spectral parameter calibration, and will provide spectral line foundation for accurate inversion of combustion flow field parameters. 2020, Chinese Lasers Press. All right reserved.
DOI10.3788/CJL202047.1011001
URL查看原文
收录类别EI
引用统计
文献类型期刊论文
条目标识符http://ir.ciomp.ac.cn/handle/181722/64676
专题中国科学院长春光学精密机械与物理研究所
推荐引用方式
GB/T 7714
Y. Zang,Z. Xu,H. Xia,A. Huang,Y. He and R. Kan. Method for Measuring High Temperature Spectral Line Parameters Based on Calibration-Free Wavelength Modulation Technology[J]. Zhongguo Jiguang/Chinese Journal of Lasers,2020,47(10).
APA Y. Zang,Z. Xu,H. Xia,A. Huang,Y. He and R. Kan.(2020).Method for Measuring High Temperature Spectral Line Parameters Based on Calibration-Free Wavelength Modulation Technology.Zhongguo Jiguang/Chinese Journal of Lasers,47(10).
MLA Y. Zang,Z. Xu,H. Xia,A. Huang,Y. He and R. Kan."Method for Measuring High Temperature Spectral Line Parameters Based on Calibration-Free Wavelength Modulation Technology".Zhongguo Jiguang/Chinese Journal of Lasers 47.10(2020).
条目包含的文件 下载所有文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
Method for Measuring(1575KB)期刊论文出版稿开放获取CC BY-NC-SA浏览 下载
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Y. Zang,Z. Xu,H. Xia,A. Huang,Y. He and R. Kan]的文章
百度学术
百度学术中相似的文章
[Y. Zang,Z. Xu,H. Xia,A. Huang,Y. He and R. Kan]的文章
必应学术
必应学术中相似的文章
[Y. Zang,Z. Xu,H. Xia,A. Huang,Y. He and R. Kan]的文章
相关权益政策
暂无数据
收藏/分享
文件名: Method for Measuring High Temperature Spectral.pdf
格式: Adobe PDF
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。