CIOMP OpenIR
Improvement of Concentration Inversion Model Based on Second Harmonic Valley Spacing in Wavelength Modulation Spectroscopy
Y. Pan,Y. Li,C. X. Yan,J. Yuan and Y. J. Ren
2020
发表期刊Ieee Access
ISSN2169-3536
卷号8页码:227857-227865
摘要In tunable diode laser absorption spectroscopy (TDLAS), the wavelength modulation spectroscopy (WMS) is widely employed. However, when measuring the gas concentration with the second harmonic signal, errors will occur and the inversion accuracy will be reduced, because the change of the modulation depth will lead to the change of the second harmonic peak value, and the value of modulation depth cannot be calculated directly in the absence of gas component. To improve the inversion accuracy of WMS technology, we calibrate the modulation depth and take it as a parameter to the concentration inversion model. In this article, the relationship between the modulation depth and the valley spacing of the second harmonic is first derived, and used to calibrate the modulation depth in the measurement; then, an improved concentration inversion model is established by adding the calibrated modulation depth to the traditional model. Through simulations in Simulink and gas concentration measurement experiments with carbon monoxide (CO), the effectiveness of modulation depth calibration using valley spacing and the accuracy of the improved model are verified. The gas concentration measurement error of the improved model (relative error < 0.37%, root-mean-square error (RMSE): 5.468 x 10(-5)) is reduced by nearly one order of magnitude compared to the traditional model without calibration of the modulation depth (relative error < 1.70%, RMSE: 2.178 x 10(-4)). The correction method of modulation depth in this article does not need the priori information of the gas component, and the improved model produces a better determination of gas concentration immune to the variations of modulation depth, which is important for field measurements especially those with large environmental variations.
DOI10.1109/access.2020.3045587
URL查看原文
收录类别SCI ; EI
语种英语
引用统计
文献类型期刊论文
条目标识符http://ir.ciomp.ac.cn/handle/181722/64598
专题中国科学院长春光学精密机械与物理研究所
推荐引用方式
GB/T 7714
Y. Pan,Y. Li,C. X. Yan,J. Yuan and Y. J. Ren. Improvement of Concentration Inversion Model Based on Second Harmonic Valley Spacing in Wavelength Modulation Spectroscopy[J]. Ieee Access,2020,8:227857-227865.
APA Y. Pan,Y. Li,C. X. Yan,J. Yuan and Y. J. Ren.(2020).Improvement of Concentration Inversion Model Based on Second Harmonic Valley Spacing in Wavelength Modulation Spectroscopy.Ieee Access,8,227857-227865.
MLA Y. Pan,Y. Li,C. X. Yan,J. Yuan and Y. J. Ren."Improvement of Concentration Inversion Model Based on Second Harmonic Valley Spacing in Wavelength Modulation Spectroscopy".Ieee Access 8(2020):227857-227865.
条目包含的文件 下载所有文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
Pan-2020-Improvement(1112KB)期刊论文出版稿开放获取CC BY-NC-SA浏览 下载
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Y. Pan,Y. Li,C. X. Yan,J. Yuan and Y. J. Ren]的文章
百度学术
百度学术中相似的文章
[Y. Pan,Y. Li,C. X. Yan,J. Yuan and Y. J. Ren]的文章
必应学术
必应学术中相似的文章
[Y. Pan,Y. Li,C. X. Yan,J. Yuan and Y. J. Ren]的文章
相关权益政策
暂无数据
收藏/分享
文件名: Pan-2020-Improvement of Concentration Inversio.pdf
格式: Adobe PDF
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。