CIOMP OpenIR
Flatness Measurement of a Mosaic Focal Plane by using a Coaxial Multispectral Laser
C. H. Liu,N. X. Guo,J. L. Wang,T. Chen,Z. Y. Wu and X. Cheng
2020
发表期刊Journal of the Korean Physical Society
ISSN0374-4884
卷号77期号:8页码:653-661
摘要The wide-field telescope will be an important tool in the discovery and birth of new theories of astronomy in future. The detectors in this kind of telescope mostly adopt a mosaic focal plane array. The focal depth of a large-F-number optical system is very small, and the flatness of the mosaic detector should be less than half the focal depth. In this paper, a new flatness measurement and data processing method is developed. A flatness measurement platform composed of a high-precision gantry platform and a coaxial multispectral displacement meter was built. The flatness of a single detector was measured under uncooled and cooled working conditions, and data processing was conducted, in which the root mean square (RMS) and the peak-valley (PV) values of the cooled detector were 0.0017 mm and 0.0112 mm, respectively. Next, a 2 x 6 mosaic model of the focal plane with a dimension of 148.5 mm x 168.5 mm was built using a metal detector model. The measurement platform was used to measure the flatness of the mosaic focal plane. According to the measurement results, the preliminary installation and mosaic adjustment were completed. The final RMS and PV values of the mosaic focal plane are 0.009 mm and 0.0808 mm, respectively. The experimental results show that the measurement and the data processing method can accurately reflect surface information on the detectors. This suggests that the method has great potential for use in ensuring the accuracy of wide-field telescope equipment in all applicable research areas.
DOI10.3938/jkps.77.653
URL查看原文
收录类别SCI
语种英语
引用统计
文献类型期刊论文
条目标识符http://ir.ciomp.ac.cn/handle/181722/64532
专题中国科学院长春光学精密机械与物理研究所
推荐引用方式
GB/T 7714
C. H. Liu,N. X. Guo,J. L. Wang,T. Chen,Z. Y. Wu and X. Cheng. Flatness Measurement of a Mosaic Focal Plane by using a Coaxial Multispectral Laser[J]. Journal of the Korean Physical Society,2020,77(8):653-661.
APA C. H. Liu,N. X. Guo,J. L. Wang,T. Chen,Z. Y. Wu and X. Cheng.(2020).Flatness Measurement of a Mosaic Focal Plane by using a Coaxial Multispectral Laser.Journal of the Korean Physical Society,77(8),653-661.
MLA C. H. Liu,N. X. Guo,J. L. Wang,T. Chen,Z. Y. Wu and X. Cheng."Flatness Measurement of a Mosaic Focal Plane by using a Coaxial Multispectral Laser".Journal of the Korean Physical Society 77.8(2020):653-661.
条目包含的文件 下载所有文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
Liu-2020-Flatness Me(2433KB)期刊论文出版稿开放获取CC BY-NC-SA浏览 下载
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[C. H. Liu,N. X. Guo,J. L. Wang,T. Chen,Z. Y. Wu and X. Cheng]的文章
百度学术
百度学术中相似的文章
[C. H. Liu,N. X. Guo,J. L. Wang,T. Chen,Z. Y. Wu and X. Cheng]的文章
必应学术
必应学术中相似的文章
[C. H. Liu,N. X. Guo,J. L. Wang,T. Chen,Z. Y. Wu and X. Cheng]的文章
相关权益政策
暂无数据
收藏/分享
文件名: Liu-2020-Flatness Measurement of a Mosaic Foca.pdf
格式: Adobe PDF
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。