CIOMP OpenIR
Flat-field calibration method for large diameter survey mirror aperture splicing
S.-t. Lu,T.-y. Zhang and X.-h. Zhang
2020
发表期刊Chinese Optics
ISSN20951531
卷号13期号:5页码:1094-1102
摘要The accurate flat-field calibration of large-diameter space survey telescopes is an important prerequisite for achieving some established scientific goals. At present, it is common practice to provide a uniform flat-field reference through a flat-field screen or a large-diameter integrating sphere, which is used to check the consistency of an image's plane response. To address issues with the uniformity of flat-field screen illumination and the difficulty of preparing large-size integrating spheres, a flat-field calibration method based on sub-aperture scanning is proposed in this paper, which improves the uniformity of the flat-field reference and the uncertain calibration caused by stray light. First, we complete a sub-aperture flat-field calibration theory analysis, establish a sub-aperture flat-field calibration mathematical model, plan the sub-aperture scanning route and scan aperture size, and perform the initial design of the parameters of the collimation system for calibration. Secondly, we complete the image surface illumination simulation verification experiment. Finally, we set up an experiment to scan the planned sub-apertures, build full-aperture illuminance data, and verify the feasibility of the above-mentioned large-aperture space survey telescope sub-aperture stitching flat-field calibration scheme. The experimental results show that the full-aperture illuminance information can be restored using the full-aperture stitching method to scan the image surface energy of the system and by using the sub-aperture stitching method to compare and contrast the full-aperture image surface illuminance. The superimposed gray value in our experiment was 233.350 and the error was 1%. It is therefore verified that the sub-aperture stitching method can be used for flat-field calibration of large-diameter sky survey telescopes, and has practical value in real-world applications. Copyright 2020 Chinese Optics. All rights reserved.
DOI10.37188/CO.2019-0252
URL查看原文
收录类别EI
引用统计
文献类型期刊论文
条目标识符http://ir.ciomp.ac.cn/handle/181722/64531
专题中国科学院长春光学精密机械与物理研究所
推荐引用方式
GB/T 7714
S.-t. Lu,T.-y. Zhang and X.-h. Zhang. Flat-field calibration method for large diameter survey mirror aperture splicing[J]. Chinese Optics,2020,13(5):1094-1102.
APA S.-t. Lu,T.-y. Zhang and X.-h. Zhang.(2020).Flat-field calibration method for large diameter survey mirror aperture splicing.Chinese Optics,13(5),1094-1102.
MLA S.-t. Lu,T.-y. Zhang and X.-h. Zhang."Flat-field calibration method for large diameter survey mirror aperture splicing".Chinese Optics 13.5(2020):1094-1102.
条目包含的文件 下载所有文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
Flat-field calibrati(5066KB)期刊论文出版稿开放获取CC BY-NC-SA浏览 下载
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[S.-t. Lu,T.-y. Zhang and X.-h. Zhang]的文章
百度学术
百度学术中相似的文章
[S.-t. Lu,T.-y. Zhang and X.-h. Zhang]的文章
必应学术
必应学术中相似的文章
[S.-t. Lu,T.-y. Zhang and X.-h. Zhang]的文章
相关权益政策
暂无数据
收藏/分享
文件名: Flat-field calibration method for large diamet.pdf
格式: Adobe PDF
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。