Changchun Institute of Optics,Fine Mechanics and Physics,CAS
Development of a two-line DLAS sensor for liquid film measurement | |
H. N. Yang,Y. F. Guo,C. L. Li,J. Tao,Y. X. Zhang,W. W. Wu and M. X. Su | |
2020 | |
发表期刊 | Spectrochimica Acta Part a-Molecular and Biomolecular Spectroscopy |
ISSN | 1386-1425 |
卷号 | 224页码:9 |
摘要 | The simultaneous measurements of multiple parameters (film thickness, temperature, etc.) of the liquid films are crucial for the design and optimization of relevant industrial processes. Here, a sensor based on diode-laser absorption spectroscopy (DLAS) was developed to simultaneously measure liquid water film thicknesses and temperatures by combining two diode lasers at different wavenumber positions, 6718.2 cm(-1) and 7040.8 cm(-1). Serious beam steering effects can be avoided by adding an integrating sphere to improve the performance of the sensor for the investigations of dynamic films. The measurement accuracies of this sensor were firstly validated by a calibration tool with known film thicknesses and temperatures. It revealed that the averaged deviations between the measured film thicknesses/temperatures and the corresponding known parameters were 4.58% and 1.34%, respectively. The sensor was then employed to study liquid film evaporation processes on a horizontal quartz glass plate. The imaging method and the thermocouple were simultaneously employed to obtain the film thicknesses and temperatures to compare with the DLAS results. It showed that the average evaporation rates of the liquid films were 0.34/0.41/0.57 mu m/s at different temperatures (340/360/390 K) of the heat gun outlet, respectively, and the evaporation rates increased with the increasing film temperatures. The whole evaporation process can be tracked with the sensor. Furthermore, the sensor was applied to simultaneously determine the variations of liquid film thicknesses and temperatures in a flow channel. It was found that the film temperatures remained almost constant during passage of low-amplitude surface waves at the film temperatures 308/315/323 K. (C) 2019 Elsevier B.V. All rights reserved. |
DOI | 10.1016/j.saa.2019.117420 |
URL | 查看原文 |
收录类别 | SCI ; EI |
语种 | 英语 |
引用统计 | |
文献类型 | 期刊论文 |
条目标识符 | http://ir.ciomp.ac.cn/handle/181722/64440 |
专题 | 中国科学院长春光学精密机械与物理研究所 |
推荐引用方式 GB/T 7714 | H. N. Yang,Y. F. Guo,C. L. Li,J. Tao,Y. X. Zhang,W. W. Wu and M. X. Su. Development of a two-line DLAS sensor for liquid film measurement[J]. Spectrochimica Acta Part a-Molecular and Biomolecular Spectroscopy,2020,224:9. |
APA | H. N. Yang,Y. F. Guo,C. L. Li,J. Tao,Y. X. Zhang,W. W. Wu and M. X. Su.(2020).Development of a two-line DLAS sensor for liquid film measurement.Spectrochimica Acta Part a-Molecular and Biomolecular Spectroscopy,224,9. |
MLA | H. N. Yang,Y. F. Guo,C. L. Li,J. Tao,Y. X. Zhang,W. W. Wu and M. X. Su."Development of a two-line DLAS sensor for liquid film measurement".Spectrochimica Acta Part a-Molecular and Biomolecular Spectroscopy 224(2020):9. |
条目包含的文件 | 下载所有文件 | |||||
文件名称/大小 | 文献类型 | 版本类型 | 开放类型 | 使用许可 | ||
Development of a two(981KB) | 期刊论文 | 出版稿 | 开放获取 | CC BY-NC-SA | 浏览 下载 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论