Design of Extremely Sensitive Refractive Index Sensors in Infrared for Blood Glucose Detection
S. K. Chamoli,S. C. Singh and C. L. Guo
2020
发表期刊Ieee Sensors Journal
ISSN1530-437X
卷号20期号:9页码:4628-4634
摘要Simple and easy to fabricate sensors with high sensitivity, high quality-factor (chi), large figure of merit (FOM), and narrow bandwidth are highly desirable for immediate point of care testing. In this article, we introduce a one-dimensional periodic array of barium flint glass on active plasmonic material, a thin gold film on silicon nitride (Si-3 N-4) substrate. Reflection spectrum of the proposed structure exhibits a clear rejection of certain wavelength on normal incidence due to the coupling between incident plane wave and plasmonic wave. The effect of ambient refractive index or glucose concentration has been studied to measure the plasmonic sensitivity of the designed structure in blood glucose detection. After optimizing geometric parameters, the designed sensor achieved sensitivity and quality factor as high as similar to 2600 nm RIU-1 (refractive index unit) and similar to 1500 respectively. The calculated sensitivity, quality factor and FOM are much higher than the reported structures with a similar geometry in IR. Owing only one rejection band with narrow bandwidth, the designed structure can also be realized for optical filtering applications. Wide spectral tunability in the IR, close to 100% peak absorbance and narrow bandwidth make the designed structures as an ideal candidate for surface-enhanced infrared absorption (SEIRA) spectroscopy.
DOI10.1109/jsen.2020.2964715
URL查看原文
收录类别SCI ; EI
语种英语
引用统计
文献类型期刊论文
条目标识符http://ir.ciomp.ac.cn/handle/181722/64427
专题中国科学院长春光学精密机械与物理研究所
推荐引用方式
GB/T 7714
S. K. Chamoli,S. C. Singh and C. L. Guo. Design of Extremely Sensitive Refractive Index Sensors in Infrared for Blood Glucose Detection[J]. Ieee Sensors Journal,2020,20(9):4628-4634.
APA S. K. Chamoli,S. C. Singh and C. L. Guo.(2020).Design of Extremely Sensitive Refractive Index Sensors in Infrared for Blood Glucose Detection.Ieee Sensors Journal,20(9),4628-4634.
MLA S. K. Chamoli,S. C. Singh and C. L. Guo."Design of Extremely Sensitive Refractive Index Sensors in Infrared for Blood Glucose Detection".Ieee Sensors Journal 20.9(2020):4628-4634.
条目包含的文件 下载所有文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
Design of Extremely (1411KB)期刊论文出版稿开放获取CC BY-NC-SA浏览 下载
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[S. K. Chamoli,S. C. Singh and C. L. Guo]的文章
百度学术
百度学术中相似的文章
[S. K. Chamoli,S. C. Singh and C. L. Guo]的文章
必应学术
必应学术中相似的文章
[S. K. Chamoli,S. C. Singh and C. L. Guo]的文章
相关权益政策
暂无数据
收藏/分享
文件名: Design of Extremely Sensitive Refractive Index.pdf
格式: Adobe PDF
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。