CIOMP OpenIR
Application of adaptive optics coherence tomography in retinal high resolution imaging
W. Fan, Z. Wang, B. Chen, T. Chen and Q. An
2020
发表期刊Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering
ISSN10072276
卷号49期号:10
摘要Retinal optical coherence tomography (OCT) technology uses external low coherence light source to irradiate the fundus of the human eye, and interfere scattered signals of the fundus of the human eye to obtain the sectional image information of the human retina, so as to realize the non-invasive, real-time and in vivo optical biopsy of the human retina. The axial resolution of traditional optical coherence tomography in retinal imaging can reach more than 3 m, but the transverse resolution of OCT can only reach about 15-20 m due to individual differences and inevitable aberrations. Adaptive optics, as an advanced technology of wavefront correction, can correct OCT chromatic aberration and aberrations caused by limited field of view and eye movement, so as to improve the transverse resolution of OCT to less than 2 m. Adaptive optics OCT can realize near diffraction limit imaging of retinal cells and microvessels to timely detect the early lesions in patients with fundus. Based on the introduction of the technical characteristics of adaptive optics and retinal optical coherence tomography, the development status of adaptive optics in retinal optical coherence tomography at home and abroad was reviewed, and the key technologies and future development trends of adaptive optics OCT retinal high-resolution imaging in wide-band light source chromatic aberration correction, eye movement artifact reduction, adaptive optics field of view expansion and wavefront sensing and correction system simplification were summarized, so as to realize high-speed retinal imaging with large field of view, high efficiency, high sensitivity and high resolution, and provide reference for the future research and application of adaptive optics OCT retinal imaging technology. Copyright 2020 Infrared and Laser Engineering. All rights reserved.
DOI10.3788/IRLA20200333
URL查看原文
收录类别EI
引用统计
文献类型期刊论文
条目标识符http://ir.ciomp.ac.cn/handle/181722/64313
专题中国科学院长春光学精密机械与物理研究所
推荐引用方式
GB/T 7714
W. Fan, Z. Wang, B. Chen, T. Chen and Q. An. Application of adaptive optics coherence tomography in retinal high resolution imaging[J]. Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering,2020,49(10).
APA W. Fan, Z. Wang, B. Chen, T. Chen and Q. An.(2020).Application of adaptive optics coherence tomography in retinal high resolution imaging.Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering,49(10).
MLA W. Fan, Z. Wang, B. Chen, T. Chen and Q. An."Application of adaptive optics coherence tomography in retinal high resolution imaging".Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering 49.10(2020).
条目包含的文件 下载所有文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
Application of adapt(824KB)期刊论文出版稿开放获取CC BY-NC-SA浏览 下载
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[W. Fan, Z. Wang, B. Chen, T. Chen and Q. An]的文章
百度学术
百度学术中相似的文章
[W. Fan, Z. Wang, B. Chen, T. Chen and Q. An]的文章
必应学术
必应学术中相似的文章
[W. Fan, Z. Wang, B. Chen, T. Chen and Q. An]的文章
相关权益政策
暂无数据
收藏/分享
文件名: Application of adaptive optics coherence tomog.pdf
格式: Adobe PDF
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。