CIOMP OpenIR
CO2 concentration detection system for seed respiration
L.-Q.Jia; H.-N.Qi; W.-J.Hu; G.-W.Zhao; R.-F.Kan
2019
发表期刊Guangxue Jingmi Gongcheng/Optics and Precision Engineering
ISSN1004924X
卷号27期号:6页码:1397-1404
摘要To address the problem of low detection accuracy in the traditional method of seed-breathing CO2 concentration measurement, a seed-breathing measurement system based on tunable diode laser absorption spectroscopic technology was proposed to meet the needs of seed-breathing CO2 concentration measurements. First, the system was designed to consist of a seed-breathing container, a distributed feedback laser and control circuit, photoelectric conversion and an amplification circuit, a data acquisition circuit, and upper computer software. The space volume of the seed breathing container was 1.5 L, the laser source was in the 2 004-nm band, and the light path of the multiple reflection cell was 16 m. Then, based on Lambert's law and wavelength modulated absorption spectroscopy, the concentration of CO2 produced during seed respiration could be retrieved in real time using second harmonics. The stable repeatability of the CO2 concentration measurement in seed respiration is 0.033%, the linear fitting degree of CO2 concentration is 0.999 38, and the detection limit of CO2 concentration is 1.710-6. The change curve of 20-g maize seed respiration is obtained by testing waxy maize seeds. The amount of change in waxy maize seed respiration after 12 h is 2 750.510-6, and the respiration rate is 229.210-6/h. Experimental results show that the system can solve the inability for continuous measurement of CO2 concentration in seed respiration and the low precision of concentration detection. 2019, Science Press. All right reserved.
关键词Carbon dioxide,Absorption spectroscopy,Computer control systems,Computer software,Containers,Data acquisition
DOI10.3788/OPE.20192706.1397
URL查看原文
收录类别EI
引用统计
文献类型期刊论文
条目标识符http://ir.ciomp.ac.cn/handle/181722/63309
专题中国科学院长春光学精密机械与物理研究所
推荐引用方式
GB/T 7714
L.-Q.Jia,H.-N.Qi,W.-J.Hu,et al. CO2 concentration detection system for seed respiration[J]. Guangxue Jingmi Gongcheng/Optics and Precision Engineering,2019,27(6):1397-1404.
APA L.-Q.Jia,H.-N.Qi,W.-J.Hu,G.-W.Zhao,&R.-F.Kan.(2019).CO2 concentration detection system for seed respiration.Guangxue Jingmi Gongcheng/Optics and Precision Engineering,27(6),1397-1404.
MLA L.-Q.Jia,et al."CO2 concentration detection system for seed respiration".Guangxue Jingmi Gongcheng/Optics and Precision Engineering 27.6(2019):1397-1404.
条目包含的文件 下载所有文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
CO2 concentration de(2467KB)期刊论文出版稿开放获取CC BY-NC-SA浏览 下载
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[L.-Q.Jia]的文章
[H.-N.Qi]的文章
[W.-J.Hu]的文章
百度学术
百度学术中相似的文章
[L.-Q.Jia]的文章
[H.-N.Qi]的文章
[W.-J.Hu]的文章
必应学术
必应学术中相似的文章
[L.-Q.Jia]的文章
[H.-N.Qi]的文章
[W.-J.Hu]的文章
相关权益政策
暂无数据
收藏/分享
文件名: CO2 concentration detection system for seed re.pdf
格式: Adobe PDF
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。