消息
×
loading..
CIOMP OpenIR
Precision test technology of liquid refractive index using the method of minimum deviation angle
Y.-S.Sun; C.Y; H.B; Y.L
2019
发表期刊Chinese Optics
ISSN20951531
卷号12期号:4页码:826-832
摘要A self-developed container made up of a metal frame and a glass window of equal thickness is proposed to improve the test accuracy of liquid refractive index. It improves test accuracy as the manufacturing process is relatively simple, which reduces the systematic error that arises due to the transflective surface and the equal optical path of the glass window. The test method in this paper uses the minimum deviation angle method, which is mainly used for testing solid refractive index but is less frequently applied to test liquid refractive index. Because a special container is needed, the manufacturing process is more complex, and the equal optical path length of transmission glass windows are difficult to control, which will greatly affect the test results. Using the container designed in this paper, theoretical test accuracy of liquid refractive index can reach the order of magnitudes 10-6. In the experimental case of 0.2" high-precision turntable, the systematic error brought by the coupled container and the theoretical measurement accuracy of the test system can satisfy the demands in the order of magnitudes 10-6. The standard deviation of the actual measurement of an ionic liquid under the characteristic spectral line of 546.08 nm is 1.4210-6. The self-developing container meets the precise testing needs of the liquid refractive index. 2019, China Science Publishing & Media LTD. All right reserved.
关键词Refractive index,Containers,Error analysis,Errors,Ionic liquids,Light transmission,Manufacture,Stained glass
DOI10.3788/CO.20191204.0826
URL查看原文
收录类别EI
引用统计
正在获取...
文献类型期刊论文
条目标识符http://ir.ciomp.ac.cn/handle/181722/63053
专题中国科学院长春光学精密机械与物理研究所
推荐引用方式
GB/T 7714
Y.-S.Sun,C.Y,H.B,et al. Precision test technology of liquid refractive index using the method of minimum deviation angle[J]. Chinese Optics,2019,12(4):826-832.
APA Y.-S.Sun,C.Y,H.B,&Y.L.(2019).Precision test technology of liquid refractive index using the method of minimum deviation angle.Chinese Optics,12(4),826-832.
MLA Y.-S.Sun,et al."Precision test technology of liquid refractive index using the method of minimum deviation angle".Chinese Optics 12.4(2019):826-832.
条目包含的文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
Precision test techn(204KB)期刊论文出版稿开放获取CC BY-NC-SA浏览 请求全文
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Y.-S.Sun]的文章
[C.Y]的文章
[H.B]的文章
百度学术
百度学术中相似的文章
[Y.-S.Sun]的文章
[C.Y]的文章
[H.B]的文章
必应学术
必应学术中相似的文章
[Y.-S.Sun]的文章
[C.Y]的文章
[H.B]的文章
相关权益政策
暂无数据
收藏/分享
文件名: Precision test technology of liquid refractive.caj
格式: caj
此文件暂不支持浏览
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。