CIOMP OpenIR
Research on near-infrared spectrometer based on DMD
Y.Wang; H.Liu; J.Li; Z.Lu; J.Xu; B.Chen
2019
发表期刊Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering
ISSN10072276
卷号48期号:6
摘要As a new type of spatial light modulator, Digital Micromirror Device (DMD) has the advantages of high resolution, low production cost and high processing efficiency. It is very flexible to use, so the laboratory built a near infrared spectrometer based on DMD. First, the basic working principle of DMD near-infrared spectrometer was introduced. Secondly, the wavelength of spectrometer was calibrated, a method based on the correlation coefficient of the same sample absorbance curve was proposed to normalize the inter-wavelength difference, so that the inter-station difference of the wavelength was theoretically less than 0.1 nm, which meet the requirements when the model was transferred. The selection criteria of different coding templates for DMD near-infrared spectrometer were obtained by comparing the noise and signal-to-noise ratio test under strong light and weak light conditions: the scanning method was better than the Hadamard method under strong light conditions, the opposite in weak light. Finally, the actual sample gasoline and diesel were tested by the spectrometer, and the test results showed that the spectrometer performance was stable. The near-infrared spectrometer based on DMD has a detection wavelength range of 1 330 to 2 500 nm, absorbance deviation is less than 0.000 4 AU. 2019, Editorial Board of Journal of Infrared and Laser Engineering. All right reserved.
关键词Infrared spectrometers,Light modulators,Signal to noise ratio
DOI10.3788/IRLA201948.0620002
URL查看原文
收录类别EI
引用统计
文献类型期刊论文
条目标识符http://ir.ciomp.ac.cn/handle/181722/62976
专题中国科学院长春光学精密机械与物理研究所
推荐引用方式
GB/T 7714
Y.Wang,H.Liu,J.Li,et al. Research on near-infrared spectrometer based on DMD[J]. Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering,2019,48(6).
APA Y.Wang,H.Liu,J.Li,Z.Lu,J.Xu,&B.Chen.(2019).Research on near-infrared spectrometer based on DMD.Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering,48(6).
MLA Y.Wang,et al."Research on near-infrared spectrometer based on DMD".Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering 48.6(2019).
条目包含的文件 下载所有文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
Research on near inf(3306KB)期刊论文出版稿开放获取CC BY-NC-SA浏览 下载
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Y.Wang]的文章
[H.Liu]的文章
[J.Li]的文章
百度学术
百度学术中相似的文章
[Y.Wang]的文章
[H.Liu]的文章
[J.Li]的文章
必应学术
必应学术中相似的文章
[Y.Wang]的文章
[H.Liu]的文章
[J.Li]的文章
相关权益政策
暂无数据
收藏/分享
文件名: Research on near infrared spectrometer based o.pdf
格式: Adobe PDF
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。